Operator Presence
System Check
NOTE:
This procedure requires Service Password.
Operator presence sensor requires a minimum of
45.4 kg (100 lb) to actuate.
1.
While operator is in seat, power truck
ON
.
2.
See Display Panel Flowchart. At the Display
Panel, Enter Main Display, enter password,
scroll to Diagnostics,
Enter
.
3.
Scroll to Seat Symbol
Enter
. Read display.
Does display show 1.4 volts or greater?
YES:
Continue with this pro-
cedure.
NO:
Sensor Out of Range Low
(OORL) or DTC 12819 and
troubleshoot per procedure.
Continue:
While operator is out of seat, power truck
ON
.
Does display show less than 0.8 volts?
NOTE:
BEFORE PROCEEDING TO NEXT CHECK,
RETURN TO SEAT AND FASTEN SEAT BELT.
YES:
Operator presence sen-
sor is OK. Go to next check.
NO:
Operator presence sen-
sor has failed. Replace seat
sensor. See
Electrical Sys-
tem
2200SRM1337.
Operational Diagnostic Procedures
Operational Checkout
Check the Service Manual section in Hypass Online for possible updates and check pertinent Grams
Confidential/Proprietary - Do Not Copy or Duplicate
9010-05-3