background image

3 Turn on thermostat,long press it for 3-5seconds to holiday mode setting. Appear

OFF

, press

or

change to ON,then press

to confirm

opening holiday mode

4 Turn off thermostat ,long press

to enter into advanced B setting

B

1 Decrease key
2 Long press to lock /unlock

D

1 Increase key :
2 Long press to inquire external sensor temperature
3 In the Auto model, press

or

enter to

temporary manual mode

Programmable

5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced options
choose model of you need, under power on state, long press

for 3-5 seconds enter into programming

mode setting, then short press

choose: hour,minute, time period, and press

and

to adjust

data, finished setting, about 10 seconds will automatic save and exist.

1

2

3

4

5

6

Wake up

Out door

Back home

Out door

Back home

Sleep

6

00 20

8

00 15

11

30

15

13

30

15

17

00

15

22

00

15

The optimum comfort temperature is 18

-22

.

Advanced options A

Under turn off state, long press

for 3-5 seconds to access advanced A setting.

From A1 to AE, short press

to choose the option, and adjust data by

, , short press

to switch

next option.Remain about 5 seconds after finish setting will quit setting.

NO

Setting Options

Data Setting Function

Factory Default

A1

Measure Temperature
Calibration

-9-+9

0.5

Accuracy

Calibration

A2

Temperature

control

return difference setting

0.5-2.5

1

A3

Children lock setting

0:half lock

1:full lock

0

A4

Power

with

memory

function

0:Power with memory function
1:Shutdown power after power off
2:Shutdown power after power on

0

A5

Backlight sleep brightness

0: 0% of brightness
1: 50% of brightness
2: 100% of brightness

1

A6

Weekly

programming

selection

0: 5+2

1:6+1

2 :7

0

A7

Setting

temperature

lowest limit

1-10

5

A8

Setting

temperature

highest Limit

20-70

35

A9

Protection

of

low

temperature

1 :1-10

2:Exceed 10

, screen display

--

,

Low

temperature protection was cancelled.

5

AA

Protection

of

high

temperature

1:

:35

-70

2: low than 35

, screen display

--

,high

temperature protection was canceled

45

AB

Return different for high
temperature protection

1-9

2

AC

Running temperature of
open window function

1:10-20

2: low 10

,screen display

--

,

open window

function was canceled

15

AD

Running time of open
window function

10-20 min

10

AE

Reset

Long press

until whole display

Advanced options B

Under turn off state, long press

for 3-5 seconds to access advanced B setting

NO.

Setting Options

Data Setting Function

Factory Default

BN

Choose sensor

N1: only inner sensor
N2: only external sensor
N3: both sensor

N1

BC

Descaling function

0: closed

1: open

0

BO

version

V1.0

1.0

Return difference

: limit valve of external sensor is 45

for factory default (A6),value of external

sensor control return difference (A3) is 2. when temperature rise to 45

,then relay stop working and will

remind high temperature production alarm. If temperature decline to 43

relay continue to work and

heating alarm will be relieved. (it can be operated ,only when indoor temperature is lower than setting
temperature )

Sensor fault display

:please choose correct working way of built-in and external sensor, if choose

wrongly or sensor fault (breakdown),

E1

or

E2

will be displayed on the screen. Thermostat will stop

heating until the fault is eliminated

Warranty

We offer the warranty of 18 months, from the sales day. The products of our company can have lifetime

warranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale

service.