background image

Daikin 

One

+ smart thermostat

Reference Guide

Содержание One+

Страница 1: ...Daikin One smart thermostat Reference Guide...

Страница 2: ...h may result In addition in jurisdictions that require one or more licenses to service the equipment specified in this manual only licensed personnel should servise the equipment Improper installation...

Страница 3: ...32 Step 2 Communication 33 Step 3 Equipment Set up 34 How to Configure Humidifier on Modulating and 2 stage Furnaces 35 How to Configure Heat Kit 35 How to Set up Lockout Temperature for Heat Pump 37...

Страница 4: ......

Страница 5: ...Introduction...

Страница 6: ...any menu with a single tap An integrated Wi Fi radio connects to the internet via a home router to the cloud and onto the homeowner mobile application The Daikin cloud will also seamlessly integrate...

Страница 7: ...7 Turning the dial changes the temperature set point A number of screen savers are available including this analog clock 1 4 5 2 3 INTRODUCTION...

Страница 8: ...to help answer questions during the installation and commissioning Scanning the bar code on the bottom left corner will link you to a website related to the title of the card For further details on th...

Страница 9: ...er for communicating HVAC systems Indoor Unit Furnace Coil Air Handler Blower DM97MC DC97MC DM96VC DC96VC DM80VC DC80VC CAPE CHPE DVFEC DVPEC DVPVC DVPTC MBVC Outdoor Unit Air Conditioner DX20VC DX17V...

Страница 10: ...y 5 from the floor On an interior wall using the included screws Important Notes You do not need the trim plate to mount the thermostat Screws included are designed to mount in sheetrock or studs Its...

Страница 11: ...t to communicating outdoor units Connect 1 2 C and R from the Daikin One to 1 2 C and R at the indoor unit Connect wires 1 and 2 from the indoor unit to 1 and 2 at the outdoor unit Wiring communicatin...

Страница 12: ...move the connector to the far left to pair R C G W1 on the 9 pin with 1 2 R C on the indoor PCB Communicating outdoor units supplied with a 7 pin connector only will move the connector to the far lef...

Страница 13: ...s with a 4 pin connector supplied will match 1 2 R C on the 4 pin with 1 2 R C on the indoor PCB Communicating outdoor units with a 4 pin connector supplied will match 1 2 on the 4 pin with 1 2 on the...

Страница 14: ...14 Wiring Diagram...

Страница 15: ...length of wire is 125 ft Communicating OUTDOOR UNIT DX17VSS Compatible Communicating INDOOR UNIT Daikin One Smart Thermostat Communicating FIT System with AHU Plug Play System Only four wires require...

Страница 16: ...16 Wiring Diagram...

Страница 17: ...d HUM OUT HUM IN must be powered with the desired voltage 24 VAC from the R terminal or 115 VAC from L1 terminal Humidification relay turns ON when there is call for heat and a call for humidification...

Страница 18: ...ixing all the wiring issues apply power Check for 24 VAC across R 24 VAC and C 24 VAC common terminals If there are still problems discovering the indoor or outdoor equipment then check for bias readi...

Страница 19: ...ts terminal blocks Take Bias readings on CAPE EEV coil if connected by repeating above steps on its terminal blocks The Bias readings should match on all the equipment s terminal blocks If Bias readin...

Страница 20: ...20 Wiring Troubleshooting View of the DS1 Switch on the Outdoor Unit PC Boards 1 17 SEER Daikin Fit...

Страница 21: ...21 INTRODUCTION 2 18 SEER all tonnage...

Страница 22: ...22 Wiring Troubleshooting 3 20 SEER 2 and 3 Ton...

Страница 23: ...23 INTRODUCTION 4 20 SEER 4 Ton...

Страница 24: ...24 Wiring Troubleshooting 5 20 SEER 5 Ton...

Страница 25: ......

Страница 26: ......

Страница 27: ...System Power Up...

Страница 28: ......

Страница 29: ...rt thermostat with the communicating indoor and outdoor systems Mount the thermostat and power ON the indoor and outdoor units The Daikin One smart thermostat gets power from the indoor unit Follow th...

Страница 30: ...ust be started with default settings Start up screen is displayed upon powering the thermostat The welcome screen displays basic instructions An explanation of two set up options is displayed on the l...

Страница 31: ...step set up process 1 Personalization 2 Communication 3 Equipment Set up 4 System Optimization 5 Preferences Full set up ensures the system is configured properly and ready for the homeowner to use N...

Страница 32: ...you to edit default information Personalization displays Language Date Time If Wi Fi is connected date time set automatically Thermostat Name Degree Units Note Tapping Daikin logo returns to welcome...

Страница 33: ...n Con gures Communication Networks Select home Wi Fi to search for networks With Wi Fi con gured the system can check the software version and update software to the latest version automatically Full...

Страница 34: ...pdf Menus and sub menus will display or not depending on the type of indoor and outdoor units detected Displays equipment found by searching the communication network or by adding removing equipment...

Страница 35: ...heat airflow trim value can be adjusted How to Configure Humidifier on Modulating and 2 stage Furnaces Refer to the Humidifier in the furnace section under Installing Daikin One section for details o...

Страница 36: ...handler heater kit size kW Select the heater kit size by scrolling available size kW options If required adjust electric heat airflow trim Installer Wizard equipment setup air handler heater kit elec...

Страница 37: ...t temperatures Backup heat is requested immediately if the difference between the heat set point and indoor temperature is greater than 4 F Depending on load conditions and system performance the ther...

Страница 38: ...ization displays System test Inverters only Charge mode Inverters only Optional test Error history Logs alerts with an error code White not critical Yellow critical Calibration Status Full set up Comm...

Страница 39: ...tionality Once selected it checks the equipment for approximately 10 15 minutes System test may exceed 15 minutes if there is an error While the system test is active test running message shows up on...

Страница 40: ...r a duration of approximately one hour while the equipment runs at full capacity During this time the contractor technician will add vapor refrigerant into the suction line while monitoring system per...

Страница 41: ...ate to system optimization calibration temperature calibration To calibrate or make adjustment to the thermostat displayed temperature drag the offset up or down Adjustment can be made 7 F to 7 F in 1...

Страница 42: ...are stored in order from most recent to least recent Each error entry comprises an error code the equipment type which generated the error brief error description and a timestamp Critical errors are d...

Страница 43: ...Information Navigate to system optimization status The status menu displays data pertaining to the selected equipment The scrollable list can be accessed any time by returning to the installer set up...

Страница 44: ...ptimize your systems performance Cool Heat House settings Dealer information Reminders Note Changing preferences is not required but reminders and dealer contact information should be input Step 5 Pre...

Страница 45: ...ased on the installed equipment with accessories Once the equipment has been added a 1 24 month service reminder can be selected for the installed equipment Note The homeowner cannot edit service remi...

Страница 46: ...nced adjustments to the Daikin One will be made here How to return to Dealer Edit mode Full Set up Navigating to dealer edit will allow you to access or revisit the installer set up screen Dealer Navi...

Страница 47: ...47 SYSTEM POWER UP...

Страница 48: ...te to settings comfort target humidity Drag the value left or right to set the target humidity level Top value displays the target humidification level Bottom value displays the target dehumidificatio...

Страница 49: ......

Страница 50: ......

Страница 51: ...References...

Страница 52: ...ning content can be found on www DaikinCity com 2 What to do if equipment isn t found during discovery mode a Find the AHU but not the outdoor unit i Ensure wiring is tight as this may cause dysfuncti...

Страница 53: ...53 REFERENCES...

Страница 54: ...wner Welcome page https www daikinone com smart_thermostats oneplus welcome Contains information for homeowner for how to use Daikin One Smart Thermostat and how to use the mobile app Professional Con...

Страница 55: ...ipment Setup Air Conditioner model from CT Specifications Model Serial Control Software Version Inverter Software Version of AC Stages of HP Stages Tonnage Cool Settings Cool Airflow Trim Low speed tr...

Страница 56: ...speed trim 15 to 15 in 3 increments Intermediate speed trim 15 to 15 in 3 increments High speed trim 15 to 15 in 3 increments 10 to 10 in 2 increments Cool Profiles Profile A Profile B Profile C Prof...

Страница 57: ...out heat pump lockout temp 20 F to 65 F in 5 F increments enable aux heat lockout aux heat lockout temp 10 F to 75 F in 5 F increments Furnace model from CT Specifications Model Serial Control Softwar...

Страница 58: ...8 10 15 20 25kW Electric Heat Airflow Trim 0 to 10 in 2 steps 10 to 10 in 2 steps Heat Airflow ON Delay Heat Airflow OFF Delay Humidifier Relay Humidifier Enable with Blower None Humidification Mode O...

Страница 59: ...nts 10 to 10 in 2 increments Cool Profiles Profile A Profile B Profile C Profile D Cool Airflow ON Delay 5 10 20 30s 1 5 10 20 30s Cool Airflow OFF Delay 30 60 90 120s 0 30 60 90 120s Remove equipment...

Страница 60: ...Electronic filter Number of filters 1 2 Remove equipment Do you want to remove this equipment Yes No Zone Board Type EWC Zone Board Zone 1 radio button Additional Zone radio button Remove equipment D...

Страница 61: ...ump operation mode current critical error current minor error requested heat demand requested cool demand requested indoor CFM requested indoor fan demand requested dehumidification demand compressor...

Страница 62: ...ion demand requested dehumidification demand refrigerant type calculated superheat calculated subcool fan runtime liquid temperature suction temperature pressure sensor Furnace operation mode current...

Страница 63: ...midification overcool 0 1 2 or 3 F boost mode on off boost mode outdoor activation temperature Always ON 70 F 75 F 80 F 85 F 90 F 95 F 100 F 105 F house settings quiet mode enable quiet mode check box...

Страница 64: ...months dehumidification filter off 1 3 6 or 12 months humidifier pad off 3 6 or 12 months service reminder off 3 6 or 12 months add custom reminder Name enter text 1 24 months dealer information deal...

Страница 65: ...an experienced radio TV technician for help REMARQUE Cet quipement a t test et d clar conforme aux limites impos es aux appareils num riques de classe B conform ment la section 15 du r glement de la F...

Страница 66: ...er holes in the wall place the trim plate against the wall first Then use the included screws to secure the terminal plate to the wall sandwiching the trim plate if you re using it After connecting th...

Страница 67: ...67 Notes...

Страница 68: ...68 Notes...

Страница 69: ...69 Notes...

Страница 70: ...70 Notes...

Страница 71: ...t HVAC Heating Ventilation Air Conditioning manufacturers in the world DIL is primarily engaged in developing indoor comfort products and refrigeration systems for residential commercial and industria...

Страница 72: ...2019 For more information Sales and Technical Support 1 855 DAIKIN1 www daikincomfort com or daikinac com PM ONE ST 11 19 www daikincity com...