MAINTENANCE

 

 

The

 

FCD

 

is

 

easy

 

to

 

maintain.

 

Only

 

cleaning

 

is

 

required

 

from

 

time

 

to

 

time

 

due

 

to

 

the

 

fact

 

that

 

the

 

unit

 

is

 

mainly

 

used

 

in

 

the

 

field

 

it

 

can

 

get

 

dirty

 

easily.

 

To

 

clean

 

the

 

FCD

 

use

 

only

 

the

 

following:

 

1

 

Warm

 

water

  

2

 

Use

 

mild

 

soap

 

solution

 

(do

 

not

 

use

 

methylated

 

spirit

 

or

 

any

 

other

 

solvent

  

that

 

may

 

damage

 

the

 

FCD)

 

3

 

Ensure

 

that

 

the

 

FCD

 

discharge

 

time

 

is

 

as

 

indicated

 

in

 

the

 

table

 

below.

 

If

 

the

 

discharge

 

rate

 

is

 

slower

 

than

 

the

 

time

 

on

 

the

 

table,

 

use

 

a

 

fine

 

tool

 

to

 

clean

 

the

 

nozzle

 

hole

 

as

 

shown

 

in

 

the

 

picture

 

below.

 

 

 

 

 

 
 
 
 

 

 

 

 

 

The

 

tool

 

should

 

fit

 

in

 

the

 

hole

 

as

 

a

 

close

 

fit

 

(not

 

tight

 

or

 

loose

 

fit)

 

 

 

 

 

 

 

Содержание FCD-314

Страница 1: ...N DEVICE MODELS FCD 653 FCD 314 FCD 730 QUALITY SYSTEM ISO 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332 LIVERPOOL B C NSW 1871 AUSTRALIA Phone Int 612 9601 2022 Fax Int 612 9602 6971 Phone Nat...

Страница 2: ...HyQuest Solutions Pty Ltd FCD Copyright Page 2 Issue 3 9 Feb 2017 Contents INTRODUCTION 3 SPECIFICATIONS 4 PREPARATION 5 OPERATION 5 MAINTENANCE 7 ACCESSORIES 9 APPENDIX A 10...

Страница 3: ...a light portable device that will save hydrologists time and money The advantage of using a Field Calibration Device is that the Tipping Bucket Rain Gauges can remain fixed in their location and are...

Страница 4: ...FCD 653 653mls Used with TB3 TB4 TB6 Model FCD 730 730mls Used with HS 305 TB300 1mm TB305 1mm Nozzle The FCD comes with one nozzle rate of 200mm hr However customer can specify other rates 50 100 or...

Страница 5: ...ent that is adhered to the internal surfaces of the bucket 3 Dismantle the syphon and clean it refer to rain gauge manual or video on the link below 4 Ensure the bucket axle is tipping freely 5 Ensure...

Страница 6: ...e accuracy of the calibration results Step3 A pre set volume of water will discharge through the Tipping Bucket Rain gauge This process is to be repeated a second time for an accurate calibration chec...

Страница 7: ...ily To clean the FCD use only the following 1 Warm water 2 Use mild soap solution do not use methylated spirit or any other solvent that may damage the FCD 3 Ensure that the FCD discharge time is as i...

Страница 8: ...ce criteria Rate in mm hr FCD 653 282 82mm funnel 0 1mm rain gauge FCD 730 305mm funnel Theoretical Value Min Sec Min Accepted Min Sec Max Accepted Min Sec Theoretical Value Min Sec Min Accepted Min S...

Страница 9: ...td FCD Copyright Page 9 Issue 3 9 Feb 2017 ACCESSORIES Part No Description FCD03 50 FCD NOZZLE 50MM HR FCD03 100 FCD NOZZLE 100MM HR FCD03 200 FCD NOZZLE 200MM HR FCD03 300 FCD NOZZLE 300MM HR FCD03 5...

Страница 10: ...HyQuest Solutions Pty Ltd FCD Copyright Page 10 Issue 3 9 Feb 2017 APPENDIX A Instruction sheet for FCD 314 Used with TB3 TB4 TB6...

Страница 11: ...HyQuest Solutions Pty Ltd FCD Copyright Page 11 Issue 3 9 Feb 2017 Instruction sheet for FCD 653 Used with TB3 TB4 TB6...

Страница 12: ...HyQuest Solutions Pty Ltd FCD Copyright Page 12 Issue 3 9 Feb 2017 Instruction sheet for FCD 653 used with 159 58mm dia Rain Gauge...

Страница 13: ...HyQuest Solutions Pty Ltd FCD Copyright Page 13 Issue 3 9 Feb 2017 Instruction sheet for FCD 314 used with 159 58mm dia Rain Gauge...

Страница 14: ...HyQuest Solutions Pty Ltd FCD Copyright Page 14 Issue 3 9 Feb 2017 Instruction sheet for FCD 730 used with HS 305 TB300 1mm TB305 1mm...

Отзывы: