Maintenance and Servicing
Information
• All maintenance should be done when machinery is stationary and has been isolated from its energy sources.
It is dangerous to perform maintenance while machinery is still connected to its power source. Machinery should be
isolated from its electrical, hydraulic or gas engine power source.
• Be sure to release all pressure from the system before performing any sort of maintenance on a Hypro pump.
• DO NOT perform service or maintenance to the pump, or attached components, until the pump unit is below
109°F(43°C)
• When handling Hypro pumps one should wear steel toed shoes and protective gloves in order to protect the feet
in the event the pump is dropped and protect the hands from any sharp surfaces on the pump or chemicals. If the
pump is being repaired while the pump is in service eye protection should also be worn.
Any hazardous liquids should be disposed of in a manner which complies with local and national regulations, never dump
fluids onto the ground.
Disposal
When disposing of a Hypro pump be sure to remove all fluids from the pump before scrapping. These fluids should be
disposed of in a manner which complies with local and national regulations, never dump fluids onto the ground. Once the
pump is free of all fluids it may be scrapped in accordance with local and national laws.
Cleaning
Your pump will last longer and give best performance when properly taken care of. Proper pump care depends on the
liquid being pumped and when the pump will be used again. After each use, flush pump with a neutralizing solution for
the liquid just pumped. Follow with a clean water rinse. This is especially important for corrosive chemicals. It is good
practice to clean the pump after each use to prevent deposits from forming and damaging the pump. For infrequent use
and before long periods of storage, drain pump thoroughly. Open any drain plugs, remove suction hose from liquid, and
blow pump dry with air. A antifreeze/rust inhibitor should be injected into the pump before both ports are plugged and the
pump is stored. Plug all ports to keep out air until pump is used again.
Maintenance, Routine Servicing, and Inspection
PREVENTATIVE MAINTENANCE CHECK-LIST
Check
Daily
Weekly
Water Leaks
X
Plumbing
X
•
Each system’s maintenance cycle will be exclusive. If system performance decreases, check immediately.
•
Duty cycle, temperature, quality, type of fluid being pumped, and inlet feed conditions all affect the life of spray boom
assemblies and service cycle.