Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC
Operator Manual
810470
49
Powermax85 SYNC systems
Table 5
– 85 A CSA
Table 6
– 85 A CE/CCC
Extension cord length
< 3 m
(< 10 ft)
3 m – 7.5 m
(10 ft – 25 ft)
7.5 m – 15 m
(25 ft – 50 ft)
15 m – 30 m
(50 ft – 100 ft)
30 m – 45 m
(100 ft – 150 ft)
Input voltage (VAC)
Phase
Extension cord gauge
200 – 240
1
16 mm
2
(6 AWG)
16 mm
2
(6 AWG)
16 mm
2
(6 AWG)
25 mm
2
(4 AWG)
35 mm
2
(2 AWG)
480
1
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
10 mm
2
(8 AWG)
10 mm
2
(8 AWG)
200 – 240
3
10 mm
2
(8 AWG)
10 mm
2
(8 AWG)
10 mm
2
(8 AWG)
16 mm
2
(6 AWG)
25 mm
2
(4 AWG)
400/480
3
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
600
3
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
6 mm
2
(10 AWG)
Extension cord length
< 3 m
(< 10 ft)
3 m – 7.5 m
(10 ft – 25 ft)
7.5 m – 15 m
(25 ft – 50 ft)
15 m – 30 m
(50 ft – 100 ft)
30 m – 45 m
(100 ft – 150 ft)
Input voltage (VAC)
Phase
Extension cord gauge
380
3
6 mm
2
6 mm
2
6 mm
2
6 mm
2
6 mm
2
400
3
6 mm
2
6 mm
2
6 mm
2
6 mm
2
6 mm
2
Содержание SYNC Powermax 105
Страница 1: ...Powermax65 85 105 SYNC Operator Manual 810470 REVISION 3 ENGLISH ...
Страница 8: ......
Страница 14: ...Contents 14 810470 Operator Manual Powermax65 85 105 SYNC ...
Страница 20: ...Where to Find Information 1 20 810470 Operator Manual Powermax65 85 105 SYNC ...
Страница 62: ...Install and Set Up the Plasma Power Supply 2 62 810470 Operator Manual Powermax65 85 105 SYNC ...
Страница 94: ...Operate the Plasma System 3 94 810470 Operator Manual Powermax65 85 105 SYNC ...