Troubleshoot Common Problems
6
136
810470
Operator Manual
Powermax65/85/105 SYNC
0-19-9
Yellow
Flashes
yellow
The input power stopped. Or,
power PCB hardware
protection occurred for
components in the plasma
power supply.
This fault code stops the system from operating.
Do the following.
• This fault can be the result of electrical
noise. Wait for the fault to go away, and
continue to cut.
• If you use serial communications, this fault
can occur temporarily on the CNC when
you set the plasma power supply to
OFF (
O
). Wait for 1 minute for the fault to
go away on its own.
• If this fault continues to occur, it can identify
a possible hardware fault with an internal
component. A hardware fault shows as a
1-
nn
-
n
, 2-
nn
-
n
, or 3-
nn
-
n
fault code. A
qualified service technician must repair the
system. Speak to your distributor or
authorized repair facility.
Fault
code
Fault
icon
Fault
LEDs
Description
Solutions