Troubleshoot Common Problems
6
130
810470
Operator Manual
Powermax65/85/105 SYNC
Fault codes
When a fault occurs with the plasma power supply or the torch, a fault code
and related fault
icon
show on the status screen. The yellow fault LED
also comes on.
Fault codes are in the format
N
-
nn
-
n
. The fault code value identifies the importance of the fault: the
higher the number, the higher the importance. If more than one fault occurs at the same time, the
fault code with the highest importance shows.
The Power Supply Log screen shows the 10 most recent faults. Refer to
The status LED on the SmartSYNC hand torch also shows the fault status.
The gouge does not have
enough width.
• Tilt the torch down so that it is closer to the workpiece.
• Increase the arc stretch (standoff).
• Decrease the gouging speed.
• Increase output current (A).
Refer to
Problem
Solution
1
2
3
1
2
3
Green
= prepared
to cut
Yellow
= a 0-
nn
-
n
fault code, or the
torch is locked
Red
= a 0-32-0,
1-
nn
-
n
, 2-
nn
-
n
, or
3-
nn
-
n
fault code