6 – Power Supply Component Replacement
Replace the drain hose, gas supply hoses, and 90° fitting
The power supply contains a drain hose and 2 gas supply hoses that can be replaced. See
The drain hose runs from the bottom of the air filter bowl to the base of the power supply.
One gas supply hose runs from the air filter to the solenoid valve.
The other gas supply hose runs from the solenoid valve to the torch lead.
You can also replace the plastic 90° fitting that connects the gas supply hose from the solenoid valve to the gas supply
fitting from the torch lead.
The gas supply hoses in this system use push-to-connect fittings.
How to use push-to-connect fittings
Kit number
Description
Kit: Drain hose, 2 gas supply hoses, elbow fitting
Push-to-Connect
To connect
, push the hose into the fitting until it stops. Pull on the hose to verify that it is secure.
To release
, push the fitting collet toward the fitting, and pull the hose away from the fitting.
1
2
3
Hose
Collet
O-ring
1
2
3
Содержание Powermax30 AIR
Страница 6: ......
Страница 24: ...24 Powermax30 AIR Service Manual 808850 1 Specifications ...
Страница 32: ...32 Powermax30 AIR Service Manual 808850 2 Power Supply Setup ...
Страница 96: ...96 Powermax30 AIR Service Manual 808850 5 Troubleshooting and System Tests ...
Страница 183: ...Powermax30 AIR Service Manual 808850 183 6 Power Supply Component Replacement Figure 92 2 3 4 1 ...
Страница 184: ...184 Powermax30 AIR Service Manual 808850 6 Power Supply Component Replacement ...
Страница 200: ...200 Powermax30 AIR Service Manual 808850 7 Torch Component Replacement ...
Страница 222: ...Powermax30 AIR Service Manual 808850 222 9 Wiring Diagrams Powermax30 AIR schematic 013393 Rev A SHEET 1 of 2 ...
Страница 223: ...Powermax30 AIR Service Manual 808850 223 9 Wiring Diagrams 013393 Rev A SHEET 2 of 2 ...