5 – Troubleshooting and System Tests
Test 6 – plasma start
Use this test to make sure the control board LED is receiving a valid start signal.
1.
Set the power switch to OFF (
O
), and disconnect the power cord from the power source.
2.
Remove the power supply handle and cover. See
3.
Remove the component barrier. See
4.
Reconnect the electrical power and turn the power ON (
I
).
5.
Quickly tap the torch trigger to force gas flow without firing an arc, and watch the Start LED on the control board.
The Start LED should illuminate whenever the trigger is pulled. See
on page 71 for the location
of the Start LED.
6.
Turn OFF (
O
) the power.
WARNING!
While testing, do not touch the nozzle at the end of the torch. Dangerous voltages can
cause serious injury.
WARNING!
ELECTRIC SHOCK CAN KILL
Use extreme caution when working near live electrical circuits. Dangerous
voltages exist inside the power supply that can cause serious injury or death.
on page 57 before proceeding.
Содержание Powermax30 AIR
Страница 6: ......
Страница 24: ...24 Powermax30 AIR Service Manual 808850 1 Specifications ...
Страница 32: ...32 Powermax30 AIR Service Manual 808850 2 Power Supply Setup ...
Страница 96: ...96 Powermax30 AIR Service Manual 808850 5 Troubleshooting and System Tests ...
Страница 183: ...Powermax30 AIR Service Manual 808850 183 6 Power Supply Component Replacement Figure 92 2 3 4 1 ...
Страница 184: ...184 Powermax30 AIR Service Manual 808850 6 Power Supply Component Replacement ...
Страница 200: ...200 Powermax30 AIR Service Manual 808850 7 Torch Component Replacement ...
Страница 222: ...Powermax30 AIR Service Manual 808850 222 9 Wiring Diagrams Powermax30 AIR schematic 013393 Rev A SHEET 1 of 2 ...
Страница 223: ...Powermax30 AIR Service Manual 808850 223 9 Wiring Diagrams 013393 Rev A SHEET 2 of 2 ...