3-15
Service Manual
M
AINTENANCE
Resistance Values
a)
Tolerance
±
10 % unless specified
b)
Turn Off (O) and remove input power
plug from receptacle before checking resistance.
R1
All values for T1 are less than 1 ohm
Voltage Readings
a) Tolerance
±
10 % unless specified
b) Reference - to circuit common, lead 43 unless noted
V1
115 VAC
V2
200 VAC
V4
170 VAC
V5, V6, V7
18 VAC
V8
24 VAC
V9
265 VDC open-circuit voltage
V10
22.5 VDC during pilot arc
V11
12 VDC
V12, V13
24 VDC
V14
265 VDC open-circuit voltage
Figure 3-4.2 Wiring Diagram, 200 Volt
V11
V12
V14
V10
Power-Up
Delay Relay
Requires 40
PSI (2.8 bar)
to close S3
V13
7-98