Boost Pump and Fan Motor Starters
The boost motor starter uses an integrated starter and thermal overload device.
The optional fan motor starter is similar to the boost motor starter. The overload
setting has been factory set and should not be adjusted unless instructed to do so
by an authorized Hypertherm service representative. To reset the
OL-BOOST
or
OL-FAN
turn the dial to
RESET
and then back to
AUTO
. If your shop has high
water pressure it is possible that the boost pump would elevate the water pressure
beyond the 125psi maximum. In this case, you should turn the dial switch to off
and run without the boost pump. In addition, you will need to disable the Boost
Fault Monitoring setting in the PLC. Contact Hypertherm or refer to the
supplemental control manual for information on changing this setting.
Motor Service
Boost Motor Replacement and Direction Check
In rare cases, the boost motor may need to be replaced. If the
boost motor is in need of replacement always make sure to wire
the new motor following the proper wiring diagram for the 3
phase voltage of your pump. After replacing the motor, it is
necessary to perform a rotational direction check. Take the
following steps to ensure that the motor and boost pump are not
damaged from improper rotation.
1.
Remove the front and rear cover from the pump.
Make sure that you can see the boost motor coupling through the pump mount. It
may be necessary to have two people for this procedure.
2.
To
jog
the motor, pull the
EMERGENCY STOP
button on the control panel, and then press the
CONTROLS ON
button.
3.
Press
(PUMP ON)
and then quickly press
(PUMP OFF)
to jog the motor.
4.
Verify visually that the shaft is rotating the same way the pump rotation arrow indicates.
If the motor rotates in the wrong direction, swap the pair of wires at the bottom of the boost motor
starter
MS-BOOST
. Perform the previous steps again to make sure the rotation has reversed.
After verifying motor rotation, replace any covers that were removed.
Main Motor Lubrication
The main motor in the Hypertherm pump needs to be greased periodically. Use a good quality,
moisture-resistant, polyurea-based grease such as Chevron SRI #2.
Do not use lithium-based grease: mixing the OEM grease with lithium grease may
result in loss of lubrication, shorter motor bearing life, and shorter motor life.
Do not over-grease the bearings. Refer to the Maintenance section of the manual
for recommended intervals to grease the motor.
28
Содержание HyPrecision 100D
Страница 1: ...Instruction Manual 808310 Revision 0 English Original instructions ...
Страница 2: ...Instruction Manual 808310 Revision 0 English March 2014 Hypertherm Inc Hanover NH 03755 USA ...
Страница 16: ...14 ...
Страница 24: ...22 ...
Страница 27: ...25 ...
Страница 34: ...32 ...
Страница 58: ...56 ...
Страница 74: ...72 ...
Страница 75: ...12 Drawings and Parts Lists 73 ...
Страница 76: ...74 ...
Страница 77: ...13 Controls Manual 75 ...