Adjusting the Cut and Pierce Pressure
The cut pressure and pierce pressure can be adjusted using the knobs on the front of the pump. To adjust
the cut and pierce settings for pumps equipped with Analog Pressure Control, refer to the following
section. To adjust the cut and pierce pressure, the pump must be running.
To adjust cut pressure, the
CUT PRESSURE
icon
must be active (light blue). Touch the icon to
activate the cut pressure. To increase cut pressure, turn the cut pressure knob clockwise. To decrease cut
pressure, turn the knob counterclockwise.
To adjust the pierce pressure, the
PIERCE
PRESSURE
icon
must be active (light blue). Touch
the icon to activate the pierce pressure. To increase pierce pressure, turn the pierce pressure knob
clockwise. To decrease pierce pressure, turn the knob counterclockwise.
If the set point of the cut pressure is lower than the set point of the pierce
pressure in the PIERCE mode, the pump will operate at the lower cut pressure.
Tip:
To extend the life of your high-pressure seals and other high pressure components, turn the cut
pressure all the way down by backing out the cut pressure knob
before
shutting off the pump. When
restarting the pump, slowly ramp up the cut pressure knob until you are at the desired set point.
Analog Pressure Control
Pumps that are equipped with Analog Pressure Control operate similar to the standard pumps. The set
point values on the analog pressure control adjust with the OCS rather than the control knobs.
To adjust cut pressure, the
CUT PRESSURE
icon
must be active (light blue).
Touch the icon to activate the cut pressure. To increase cut pressure, push
on the display.
To decrease cut pressure, push
on the display.
To adjust the pierce pressure, the
PIERCE PRESSURE
icon
must be active (light blue). Touch
the icon to activate the pierce pressure. To increase pierce pressure, push
on the display. To decrease
pierce pressure, push
on the display.
Remote Pump Operation
Hypertherm HyPrecision 100D/150D Intensifier Pumps come standard with built-in functionality for
remote operation. Information on wiring connections is provided in
Electrical Control Panel
in the
Electrical System
section of the manual.
Remote Pump Control (RPC)
deactivates the
CONTROLS ON
,
PUMP ON
, and
COOLING ON
at
the front panel of the pump. These inputs are then solely controlled from a remote source.
PUMP OFF
and
EMERGENCY STOP
are active at both the front control panel and the remote
source. RPC is activated by turning the key switch to the
REMOTE
setting.
20
Содержание HyPrecision 100D
Страница 1: ...Instruction Manual 808310 Revision 0 English Original instructions ...
Страница 2: ...Instruction Manual 808310 Revision 0 English March 2014 Hypertherm Inc Hanover NH 03755 USA ...
Страница 16: ...14 ...
Страница 24: ...22 ...
Страница 27: ...25 ...
Страница 34: ...32 ...
Страница 58: ...56 ...
Страница 74: ...72 ...
Страница 75: ...12 Drawings and Parts Lists 73 ...
Страница 76: ...74 ...
Страница 77: ...13 Controls Manual 75 ...