background image

POWER-MATE LITE “QUICK-START” OPERATING INSTRUCTIONS

Warning: This product contains live mains voltages and should be used only by an adult or under adult supervision. If 
the power cord or case becomes damaged, please return to either the manufacturer or an authorised service com-
pany for repair. Do not use in wet areas or if the unit becomes wet.

INTRODUCTION

The Power-Mate Lite (PML) reveals Running cost, Energy use, Greenhouse Gas (G/Gas) all expected Meter readings 
(including VA & PF) and it has a selectable timer function built in for taking readings over a preset period.

TERMS USED IN THIS MANUAL

The Power-Mate Lite (PML) screen shows multiple lines of data at the same time.

There are 3 buttons, which you either “click” with a short press or “hold” with a long press.

The “Zoom” button selects a line to magnify by clicking, or zooms into the line by holding.

The “Menu” button changes between the screens for Cost, Greenhouse Gas, Energy, Meter and Timing by clicking, 
or enters the setting mode for Cost, G/Gas and the Timer screen by holding.

The “Run” button starts, stops or pauses a measurement by clicking the button or resets the meter and clears all 
data by holding.

In the Time screen, a convenient count-down timer can be set by choosing between 9 selectable preset times or 
“Not Set”. If “Not Set ” is chosen, the Timer counts time up from zero and the display shows the total measurement 
elapsed time or Runtime. If a time period is selected though, the display then shows the time remaining or Endtime
for the measurement.

ENTERING INITIAL COST AND GREENHOUSE GAS (G/GAS) DATA

When delivered from new, the Power-Mate Lite will be prompting you to enter the cost value of your electricity when 
power is first applied. To obtain best accuracy, the cost must be entered in cents per kilowatt-hour (kWh) from your 
energy providers’ most recent account.

Note:   1) Some energy providers refer to kWh as units. PML’s are shipped preset to 18c/kWh.
   

2) You must first be in either the Cost or G/Gas screens to be able to set their values, then simply hold the  

   

   “menu” button depressed until the “Set” screen is displayed.

To modify the Cost or G/Gas value, click the Zoom button to change the number (this cycles through 0-9). Clicking 
the Run key moves to the next digit, like setting a typical digital clock.

Similarly, enter the greenhouse gas coefficient, which can be found on the website: www.climatechange.gov.au/ table 
#39 which is measured in kg CO2-e/kWh.

Note: the G/Gas coefficient varies from state to state – look to “Table 5: Indirect (scope 2) emission factors for  
consumption of purchased electricity from the grid” for your state’s value. If accurate figures are not available, 1.0kg 
CO2-e/kWh can be used as a reasonable approximation (units come shipped with the G/Gas value pre-set to
1.0kg CO2-e/kWh).

DISPLAY

The Cost, G-Gas and Energy screens simultaneously provide four lines of information, shown in order here:

1)  The real (or actual) figure to date (since the measurement was started).
2)  The estimated Hourly amount.
3)  The estimated Quarterly amount.
4)  The estimated Yearly amount

Содержание Power-Mate Lite

Страница 1: ...THE PML The Power Mate is intended for indoor use only Do not use the Power Mate if the case or cord is damaged Do not use the Power Mate if it becomes wet Avoid using the Power Mate in bathrooms or wet areas Use the Power Mate with sine wave power sources only ie Mains power or inverters labelled as pure sine wave Do not use the unit with Quasi sine wave or square wave inverters as the Power Mate...

Страница 2: ... no period has been selected Timer Duration Not Set then when run the PML will count time upwards continuously until manually stopped When a RUNTIME period has been selected 1 8 12 24 hours or 2 5 7 14 28 days pressing Run will load the timer with the selected run time and the displayed time will count downwards until zero is reached causing the meter to stop Note it is best to stop and clear the ...

Страница 3: ...values are calculated from the data collected to date The values are displayed and continuously updated once a measurement period is in progress ENERGY SCREEN Energy usage values are provided in kiloWatt hours for the actual hourly quarterly and yearly periods The actual value is the actual kilo Watt hours of energy consumed by the appliance since the test was started The hourly quarterly and year...

Страница 4: ...igits than the resolution specified the accuracy of any extra displayed digits is not guaranteed Legend Performance Technology PTY LTD Customer Care 1800 328 200 Internet www legend com au Email sales legend com au Setting Range Units Resolution Units Rate Setting 0 99 999 c kWh G Gas Setting 0 9 999 kg kWh Inbuilt Timer 1 8 12 24 Hours 2 5 7 14 28 Days Cost 0 999999 0 01 c Energy 0 99999 kWh 0 01...

Страница 5: ...s selected though the display then shows the time remaining or Endtime for the measurement ENTERING INITIAL COST AND GREENHOUSE GAS G GAS DATA When delivered from new the Power Mate Lite will be prompting you to enter the cost value of your electricity when power is first applied To obtain best accuracy the cost must be entered in cents per kilowatt hour kWh from your energy providers most recent ...

Страница 6: ...accuracy Complete operating instructions and specifications can be downloaded from www power mate com au WARRANTY This product is guaranteed against faulty components and workmanship for a period of 12 months from the date of purchase It is the responsibility of the purchaser to return the unit to the manufacturer or place of purchase with a copy of the sales receipt or invoice when requesting war...