![HYGIPLAS GG748 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/hygiplas/gg748/gg748_instruction-manual_2192816002.webp)
2
EN
Features
• Selectable temperature units, °C or °F
• Data hold function
• Maximum and minimum reading memory
• Stainless steel probe
• High/low alarm temperature limit setting
• Low battery indication
Technical Specification
Temperature range
-50°C to 300°C / -58°F to 572°F
Display Accuracy
• ±1°C between -20°C to 120°C / ±1.8°F between -4°F to 248°F
• ±3°C between 200°C to 300°C/±5.4°F between 392°F to 572°F
Display Resolution
0.1º over full range
Automatic power off
After idle for 10 minutes
Battery
1.5 volt, 2 x AAA or equivalent (included)
Probe size
3.5 (Ø) x 135 (L) mm
Display size
41 (W) x 30 (H) mm
Dimensions
62 (W) x 165 (H) x 19(D) mm, excluding probe
Installation
1. Unpack the thermometer with care.
2. Connect probe to the thermometer.
3. Open the battery cover and insert batteries.
4. Close t he battery cover.
5. The display will show the current temperature reading.
Operation
Power ON/OFF
1. Press [ON/OFF} to switch on thermometer
2. The thermometer will perform a self test with all display segments switched on for 2 seconds, and
then display the temperature as normal
3. Insert the probe by 25mm/1” into object and obtain reading when it becomes stable.
Select the temperature unit
Press and hold [°C/°F] for 3 seconds and release to change the temperature unit.
Data Hold
1. Press the [HOLD] button once will retain the display reading and the “Hold” icon will be flashing.
2. Press the button again will release the hold function and return to normal display.
Maximum/Minimum reading memory
1. Press the [MAX/MIN] button to display the maximum reading, and the “Max” icon will be flashing.
2. Press the button again will show the minimum reading and the “Min” icon will be flashing.
3. Press the button once more to return to normal display.