Place the softener as close as possible to 

the pressure tank (well system) or water 
meter (city water). 



Place the softener as close as possible to a 
floor drain, or other acceptable drain point 

(laundry tub, sump, standpipe, etc.). 



Connect the softener to the main water 
supply pipe BEFORE the water heater.  DO 

NOT RUN HOT WATER THROUGH THE 
SOFTENER
. Temperature of water pass-

ing through the softener must be less than 

100 deg. F. 



Keep outside faucets on hard water to 

save soft water and salt. 



Do not install the softener in a place where 

it could freeze. Damage caused by 

freezing is not covered by the war-
ranty.
 



Put the softener in a place water damage 

is least likely to occur if a leak develops. 

The manufacturer will not repair or pay for 
water damage. 



A 120 volt electric outlet, to plug the in-
cluded transformer into, is needed within 6 

feet of the softener. The transformer has 

an attached 6 foot power cable. Be sure 
the electric outlet and transformer 

are in an inside location, to protect 
from wet weather. 



If installing in an outside location, you 

must take the steps necessary to assure 
the softener, installation plumbing, wiring, 

etc., are as well protected from the ele-
ments, contamination, vandalism, etc., as 

when installed indoors. 



Keep the softener out of direct sun-
light
. The sun’s heat may soften and dis-

tort plastic parts. 

Where To Install The Softener 

Содержание 89 HIMTLC Series

Страница 1: ...alla on by applying provided with install kit NSF cer fied lubri cant to all seals 3 This system is not intended for trea ng water that is microbiologically unsafe or of unknown quality without adequa...

Страница 2: ...treating water that is microbiologi cally unsafe or of unknown quality without adequate disinfection before or after the system For your safety the information in this manual must be followed to mini...

Страница 3: ...ces Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nigh...

Страница 4: ...d bypass valve or 3 shut off valves Bypass valves let you turn off water to the softener for repairs if needed but still have water in the house pipes 5 8 OD drain line is needed for the valve drain A...

Страница 5: ...ot covered by the war ranty Put the softener in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet to...

Страница 6: ...of the parallel tank adaptor used in our dual tank products i e BIF BAF HTO HEDP etc has been redeveloped This new shorter version will also change the New flow directions OUT IN New Style Parallel Ta...

Страница 7: ...ube and flows upwards in the tank 2 regenerating the media bed It then travels to tank 1 through the center of the distribution tube and flows upwards in tank 1 and then out to the drain Settle Rinse...

Страница 8: ...his could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also included Run the drain hose to the nearest laundry tub or drain pipe This...

Страница 9: ...9 Installation...

Страница 10: ...the O ring is coated with grease 2 Connec on method of inlet and outlet connector same as the above make sure to connect according to the direc on of arrow seeing from the top view 3 It is also recom...

Страница 11: ...n close the bypass valve slowly open the inlet valve the raw water filling the tank and empty the air of the system open the valve more un l the backwash water is clean 5 Press any key to advance the...

Страница 12: ...ions The main display page shows the Flow Rate Date Time Of Day Remaining Volume and Total Volume The display will alternate between the main page and the dealer information page PROGRAM LEVEL USER AC...

Страница 13: ...E Time of day is for normal operation of system and the scheduling of the regeneration time The date is used in a diagnostic function to track the last time the sys tem regenerated HARDNESS This value...

Страница 14: ...OW valve backwash brine slow rinse fast rinse service refill The regenera on steps of UP FLOW valve brine slow rinse backwash fast rinse service refill Set the Down Flow valve as an example when the v...

Страница 15: ...Rinse the screen will display Press any key will stop fast rinse and the valve will advance to the next regenera on process Refill the screen will display Press any key will stop service refill and t...

Страница 16: ...6 Screws 8 7 85 drive gear 1 8 Connect screw 1 9 85HE main gear 1 10 Brine gear screw 1 11 Locating wheel assembly three options Down flow wheel Up flow wheel Filter wheel 1 12 85HE brine gear 1 13 Mi...

Страница 17: ...n assembly No Part description Qty No Part description Qty 1 Big O ring of Adaptor coupling 2 6 89 secure clip 2 2 Adaptor coupling of 89 control valve 2 7 89 valve connector 1 3 Small O ring of adapt...

Страница 18: ...lve body 1 2 95 secure clip 1 3 DLFC assembly optional 1S 2S 3S 4S 1 3 4 5 6 1 4 Drain elbow O ring 1 5 Drain elbow 1 2 3 4 1 6 Brine valve injector stem assembly 1 7 Spacer and seal assembly 1 8 Thre...

Страница 19: ...rine line adaptor assem bly optional BLFC 0 7gpm BLFC 0 95gpm 1 16 Injector assembly optional grey purple red white blue yellow 1 17 Injector cover O ring 1 18 Injector cover 1 19 Injector cover screw...

Страница 20: ...a to form or grow However during shipping storage installing and operating bac teria could get into the softener For this reason sanitizing as follows is suggested when in stalling Sani System Liquid...

Страница 21: ...21 Brine Tank Res Up Feeder Assembly 80030022 64 OZ PRO RESCARE...

Страница 22: ...22 Blank Page...

Страница 23: ...23 Blank Page...

Страница 24: ...ions described in the gen eral conditions of this warranty General Conditions Damage to any part of this water conditioner as a result of misuse misapplication neglect alteration accident installation...

Отзывы: