![Hydrotech 89 HIMTLC Series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/hydrotech/89-himtlc-series/89-himtlc-series_owners-manual_2192471011.webp)
11
So ener commissioning
1. This water so ening system must be properly installed
(
check the inlet and outlet, brine
line, drain line , power supply
)
and located in accordance with the installa on instruc-
ons before commissioning and pu ng into opera on.
2. The control panel using four touching keys, don’t operate the keys with thick gloves.
3. Open the bypass, rinse the inlet and outlet pipe with tap water. Change the control valve
to the “Manual Regenera on” interface, ini ate the control valve to the backwash pro-
cess.
4. Then close the bypass valve, slowly open the inlet valve, the raw water
fi
lling the tank
and empty the air of the system, open the valve more un l the backwash water is clean
5. Press any key to advance the control valve to the brine posi on, check and make sure the
vacuum is present at the mouth of brine, and the
fl
ow rate of brine draw meet the re-
quirement.
6. Proceed to advance to the RINSE posi on, allow the water to run un l it is clear. Proceed
to advance to the REFILL posi on, check that the brine valve is
fi
lling water into the brine
tank, allow the valve to re
fi
ll to the correct amount of water. Then advance to the SER-
VICE posi on, open the outlet on the bypass.
7. Put the salt for regenera on into the brine tank.
Содержание 89 HIMTLC Series