16
17
Dome Hole Cap
Dome Hole Cap
Removed
f.
Unplug the riser tube, carefully position the valve over it and turn the valve into the threads in the fiberglass tank,
tightening securely into tank. Note: Ensure that the internal O-ring in the valve fits securely over the riser tube.
Silicone grease (part # 92360) or other food grade lubricant may be applied to the O-ring to ease installation of
the riser tube.
f
NOTE:
Some medias like those used in BIF/BIFMN
Models are sacrificial and deplete faster
depending on inlet water conditions and
usage. The media replenishment is more
frequent in high water usage and more acidic
water cases. The dome hole models are avail-
able and supplied in which the dome hole is
available for a quick addition or replenish-
ment of media in the tank
DO NOT
use petroleum based lubricants as they will cause swelling of
O-ring seals.
CAUTION:
make sure the O-Ring is
free of defects. Use silicone based
lubrication (part # 92360) if neccesary
CAUTION:
Make sure that the unit is de-pressur-
ized before conducting this task.
The filter is now charged with media.