![Hydrotech 89 BAF Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/hydrotech/89-baf/89-baf_owners-manual_2192479027.webp)
26
27
Meter Cable
2X Clips
Screen
1.
3.
5.
2.
4.
2X Screws
Gasket
Injector Cap
Injector Assembly
3.
2.
4.
5.
1.
METER ASSEMBLY REPLACEMENT
(For Models Manufactured after
Valve Serial # Date of November 2015)
1.
Disconnect the meter cable from the meter.
2.
Disconnect the valve from bypass by removing clips
3.
Remove the coupling adapter from the valve
4.
Remove the meter support and then the impeller out from the coupling and
clean it
5.
Replace meter with the help of special tool and re-assemble the
removed components back in the section
CLEAN INJECTOR ASSEMBLY
1.
Remove the two screws from the injector cap
2.
Pull the injector cap and gasket
3.
Pull the injector assembly and Screen
4.
Replace/Clean screen and injector assembly and
put it back in the valve in appropriate location as
shown
5.
Put back the injector cap. Grease the injector
assembly orings and injector cap gasket. Care
should be taken to put all orings and gaskets in
place and grease them so that they dont pinch
Содержание 89 BAF