background image

Hydro

Tab

Marine Engineering

3

Table of Contents

Disclaimer

2

Installation Kit

4

Required Tools for Installation

5

Before Installation

5

Safety precautions

5

Proper Interceptor Installation in Transom

6

Interceptor Installation

7

Interceptor Installation (Indirect Air Supply)

9

Air Unit Installation

9

3DHC Controller Installation

11

Installation Schematic overview - Single Compressor Air Unit with One 3DHC Controller

13

Installation Schematic overview - Single Compressor Air Unit With Two 3DHC Controllers

13

Installation Schematic overview - Double Speed Air Unit with One 3DHC Controller

14

Installation Schematic overview - Double Speed Air Unit with Two 3DHC Controllers

14

The 3DHC Controller

15

The 3DHC Controller Functions

16

The 3DHC Controller Adaptation

17

Single Air Unit Electrical Diagram

18

Single Air Unit Pneumatic Diagram

19

Spare Parts List - Model: Interceptor SR300 (ASM-01269)

20

Spare Parts List - Model: Interceptor SR450 (ASM-01285)

21

Spare Parts List - Air Unit (ASM-01051)

22

Spare Parts List - Double Speed Air Unit (ASM-01086)

23

Troubleshooting

24

Warranty Conditions

25

Содержание 3DHC

Страница 1: ...Hydro Tab Marine Engineering SR Series 3DHC Installation Operation Manual Hydro Tab Marine Engineering...

Страница 2: ...ing Declaration of conformity This product conforms to the following Electromagnetic Compatibility EMC regulations and standards for use in marine environments CE EN 60945 Technical information and Do...

Страница 3: ...c overview Single Compressor Air Unit With Two 3DHC Controllers 13 Installation Schematic overview Double Speed Air Unit with One 3DHC Controller 14 Installation Schematic overview Double Speed Air Un...

Страница 4: ...the hull Use drill 5 5mm x 6holes 5 5mm x 6 SR300 Use drill 8 5mm 8 5mm Use drill 4mm 4mm Use drill 4mm 4mm RELAY 24V Extra 24V Relay on single head air unit only 4 Cables 3m supply cable Female 10m...

Страница 5: ...driver Drilling tool Safety precautions WARNING 4 Required Tools for Installation Sikaflex gun Marking tool pencil or marker Make sure there are no obstructions behind the drilling area tanks fuel lin...

Страница 6: ...ne correct the angle by using wedges or other means If the boat s transom has a significant curvature it is necessary to create a flat plane for the installation acceptable flatness tolerance 2mm Opti...

Страница 7: ...ill 4mm 4mm Use drill 4mm 4mm Remove the pattern and drill according to the pattern indications 5 Tape Drill all the pattern holes with a 3mm bore without removing the pattern You will need No 3 7 App...

Страница 8: ...o 5 Mount the interceptor to the transom 14 Apply Sikaflex to the interceptor You will need Sikaflex Gun 11 10 For Direct Air Supply Advise the instructions For Indirect Air Supply Use the components...

Страница 9: ...rine Engineering 9 9 Interceptor Installation indirect air supply In case of indirect air supply you can use the components included in the kit as shown in the image WARNING DO NOT MOUNT the Air Unit...

Страница 10: ...0 Connect the push in fitting After you install the hose through the transom mount the air fitting into the hose 5 Air Unit Installation 4 Pneumatic Connection Cut the 8mm pipe at the proper length an...

Страница 11: ...Hydro Tab Marine Engineering 11 3DHC Controller Installation 3 Use a 67mm hole saw drill 1 2 2 4...

Страница 12: ...Hydro Tab Marine Engineering 12 3DHC Controller Installation 3 5 6 7 8 M3 5x13 Ignition switch signal When there is no voltage from the ignition the controller does not work...

Страница 13: ...Schematic overview Single Compressor Air Unit with One 3DHC Controller Installation Schematic overview Single Compressor Air Unit With Two 3DHC Controllers Ignition E Fuse 3A FLYBRIDGE OPTIONAL Contr...

Страница 14: ...r Installation Schematic overview Double Speed Air Unit with Two 3DHC Controllers CABLE 10m FF 9 32V DC 7 I 0 AIR UNIT CABLE 3m F E Ignition Fuse 3A Ignition E Fuse 3A POWER CABLE Fuse 40A HELM CONTRO...

Страница 15: ...ower on led is flashing to confirm the setting Whenever the user presses instantaneously two diagonal press buttons the trim tabs get the preset position The saved position is stored even after switch...

Страница 16: ...second C A D B INTERCEPTOR POSITION MEMORY Press B C buttons simultaneously until the red led E blinks to save the interceptor position in the memory Next time you press B C simultaneously for 1 seco...

Страница 17: ...utedonlybyauthorisedtechniciansandonlyincaseof Controllerreplacementwithanewoneafterfailure Installationofasecondarycontrollerthatdoesnotincludedintheinitialset Flybridge 320BT 3DHC Controller Adaptat...

Страница 18: ...according to your boat s voltage 5 pole Male Connector DISTANCE FROM BATTERY CABLE SIZE up to 2 5m 2 x 2 5mm up to 4m 2 x 4mm up to 6m 2 x 6mm up to 10m 2 x 10mm AIR UNIT POWER CABLE SIZE ATTENTION T...

Страница 19: ...ROUP Pneumatic Diagram Compressor PNE 01208 Exhaust REV 00305 C1 C2 C3 C4 SYMBOL PART No DESCRIPTION NOTES C1 PNE 00017 COIL STARBOARD RETRACT C2 PNE 00017 COIL STARBOARD EXTEND C3 PNE 00017 COIL PORT...

Страница 20: ...6 SR300 BACK BODY 1 2 GEN 00508 SR300 FRONT COVER 1 3 GEN 00507 SR300 BLADE 1 8 FAS 02549 SCREW 6 1x48 23 8 9 SPR 00037 SPRING 4 BOM ID PartNo Description QTY 12 GEN 00305 FITTING COVER 1 13 GEN 00306...

Страница 21: ...DY 1 2 GEN 00522 SR450 FRONT COVER 1 3 GEN 00521 SR450 BLADE 1 8 FAS 02549 SCREW 6 1x48 23 10 9 SPR 00037 SPRING 6 BOM ID PartNo Description Qty 12 GEN 00305 FITTING COVER 1 13 GEN 00306 FITTING COVER...

Страница 22: ...BASE 1 14 LAS 00542 RELAY HOLDING FLANGE 1 15 PNE 00072 PLUG MALE PARALLEL 1 8 3 16 PNE 00552 CANNOTTO NO 9 3 2 6W 09F07401A30NN 4 17 PNE 00924 COIL EVI 7 9 10W 4 18 PNE 00926 AIR UNIT VALVE BASE 72x6...

Страница 23: ...00168 SPRING CLAMP 2 10 LAS 00114 MOUNTING BASE 1 11 PNE 00009 CAP 1 8 2 12 PNE 00047 SILENCER 1 2 1 13 PNE 00050 SILENCER 1 8 PA 1 14 PNE 00092 SAFETY VALVE 1 8 1 15 PNE 00552 PILOT NO 9 3 2 4 16 PN...

Страница 24: ...ts air Broken tubular or pipe NO Faulty Valve NO Burned coil or faulty PCB Press RIGHT button Flaps Extend Compressor operates NO YES NO Check Fuse Relay and Power Supply YES Solenoid Energized C4 C1...

Страница 25: ...tab gr product registration In case the dealer sells separate units of Interceptors Air Units and Controllers that constitute a full system that is not initially sold as a complete system by Hydrotab...

Страница 26: ...Hydro Tab Marine Engineering 26 Notes...

Страница 27: ...Hydro Tab Marine Engineering 27 Notes...

Страница 28: ...Hydro Tab Marine Engineering 28 Hydro Tab Marine Engineering 4 Papazoglou str GR 17778 Athens Greece email info hydrotab gr website www hydrotab gr REV B...

Отзывы: