12
Refer to Owner’s Manual for complete details
To CHECk/CHANGE THE SET TEMPERATuRE
The last measured temperature is constantly
displayed on the topside control. When either of these pads
is pressed once, the display will show the set temperature.
Press either pad a second time to increase or decrease the
set temperature. After 3 seconds the display will once again
show the last measured temperature.
The temperature can be adjusted from 21˚C (70˚F) to
40˚C (104˚F) in 1˚ increments
HEATER FuNCTIoN
Platinum Series, Limited & Luxury Edition: for units
connected to a 16A electrical supply service, the heater
operates only on pump 1 low speed and turns off when
either pump high-speed or blower is activated.
Titanium Series: for units connected to a 32A electrical
supply service, the heater operates with any 2 high-speed
pumps or 1 high-speed pump and blower.
PuMPS / JETS FuNCTIoN
from left to right on topside control – P1, P2, *P3
(*Titanium series only)
PuMP 1 (P1)
1
st
press – turns on low speed – the P1 icon
spins slowly
2
nd
press – turns on high speed – the P1 icon
spins faster
3
rd
press – turns off pump
– no icon displayed
when P1 is off
When P1 low is already operating, the 1
st
press of the P1
pad puts the pump directly into high speed.
Low speed P1 starts automatically every 30 minutes to
measure water temperature (in STANDARD mode only – see
mODE FUNCTION), when a filter cycle is activated, or when
a freeze condition is detected.
When P2, P3 or the blower is manually activated, P1 low
speed is automatically activated and operates until the
pump(s) or blower time out. If P2, P3 or the blower is
turned on even briefly, and then turned back off, P1 low will
operate for a minimum of 2 minutes.
PuMP 2 (P2)
1
st
press – turns on high speed – the P2 icon
spins fast
2
nd
press – turns off pump
– no icon displayed
when P2 is off.
PuMP 3 (P3) – TITANIuM SERIES oNLY
1
st
press – turns on high speed – the P3 icon
spins fast
2
nd
press – turns off pump
– no icon displayed
when P3 is off.
PuMPS AuToMATIC TIME-ouT
P1 high speed, P2 & P3 – 15 minutes
P1 low speed – 4 hours.
PuMP & bLoWER oPERATING CoNDITIoNS
Platinum Series, Limited & Luxury Edition
P1 and P2 have priority over the blower. If either pump
is on high-speed, the system will not activate the blower
until either pump automatically times-out or is manually
deactivated by the user. Alternately, if only one of the
high-speed pumps is ON and the blower is already ON, when
the second high-speed pump is activated, the blower will
turn OFF.
Example 1: If P1 and P2 high-speed are activated at the
same time, and the blower button is pressed 5 minutes later,
the blower will turn ON after a 10 minute delay (balance
of the P1 and P2 high-speed time-outs) and operate for 5
minutes (15 minutes minus 10 minutes)
Example 2: If one high-speed pump (either P1 or P2) and
blower are activated at the same time, and the second
high-speed pump button is pressed 5 minutes later, the
blower will automatically turn OFF, but the system will
continue the time-out countdown. If 5 minutes later, P1
or P2 is manually turned OFF by the user, the blower will
automatically turn ON again and operate for the 5 minutes
remaining before the end of the automatic time-out.
CLEAN-uP CYCLE
The Clean-up Cycle begins 30 minutes after the pump(s)
or blower have been turned off or have automatically
timed-out. P1 low speed and the ozonator (optional) will
operate for one hour.
SETTING THE SYSTEM CLoCk TIME
The word
TIME
flashes on the topside control display upon
initial start-up. This reminder will disappear once the clock
time is programmed.
Press
then
to enter programming mode.
To set the hour: Press
or
- each press changes the
time by 1 hour.
Press
to enter, and to continue to set minutes.
To set minutes: Press
or
- each press changes the
time by 1 minute.
Press the
pad again to continue to the filter cycle
programming mode (see below) OR Press the
pad to
exit programming mode.
During normal operation, pressing the
pad will display
the current time for 3 seconds.