10
Refer to Owner’s Manual for complete details
PuMP / JETS FuNCTIoN
Press this pad to activate the pump
1st press – turns on low speed
2nd press – turns on high speed
3rd press – turns off pump
When low speed is already operating, the 1st press of the
pad puts the pump directly into high speed.
Low speed starts automatically every 30 minutes to measure
water temperature (in STANDARD mode only – see mODE
FUNCTION), when a filter cycle is activated, or when a
freeze condition is detected.
When the blower (optional) is manually activated, the pump
low speed is automatically activated and operates until the
blower times out. If the blower is turned on even briefly,
and then turned back off, low speed will operate for a
minimum of 2 minutes.
PuMP AuToMATIC TIME-ouT
High speed
– 15 minutes
Low speed
– 4 hours
FILTER CYCLES
The system will automatically activate the pump low speed
to filter the water either once or twice each day, and can
be programmed by the user. The first filter cycle begins 6
minutes after the spa is initially powered up. The second
filter cycle begins 12 hours after the start of the first filter
cycle. The filter cycle duration - length of time the pump
low runs - is programmable from 1 to 12 hours (F1 to F12).
The factory default is 2 hours, twice daily.
PRoGRAMMING FILTER CYCLES
To change the factory default filter cycle settings
Press
then
- the current filter cycle duration will
be displayed
Press
again to adjust the filter cycle duration
Press
to exit programming mode and save changes.
bLoWER
oPTIoNAL – FACToRY INSTALLED
Press this pad to turn the blower on and off.
The system will automatically turn off the blower after
15 minutes.
PuRGE CYCLES
bLoWER oNLY
The system automatically activates the blower for 30
seconds at the beginning of each filter cycle to introduce
fresh, sanitized water into the blower plumbing circuit.
MoDE FuNCTIoN
A combination of keypads is used to change hot tub
operation to either ‘STANDARD’, ‘ECONOMY’ or ‘SLEEP’ mode.
PRoGRAMMING MoDE FuNCTIoN
Press
then
- the current mode setting will flash
on the display
Press
then
repeatedly to select mode
STANDARD MoDE
The system automatically starts the pump low speed every
30 minutes to measure water temperature, and maintain
the set temperature. The display will show
briefly, then
the last measured water temperature. The current water
temperature is displayed only after the pump has been
operating for at least 2 minutes.
ECoNoMY MoDE
The system will heat to the set temperature only
during the filter cycles. The display will show
when the
temperature is non-current. When the temperature is
current, the display will alternate between
and the
water temperature.
SLEEP MoDE
The system will heat to within 10˚C (20˚F) of the set
temperature only during filter cycles. The display will show
until the mode is changed.
STANDbY / DRAIN ASSIST
The standby/drain assist feature stops the system from
operating automatically, allowing for convenient filter
cartridge removal and for safe draining of the hot tub. The
following pads must be pressed within 3 seconds of each
other.
Press
then the
pad - the display will
flash
.
If the system is heating when Standby mode is activated,
will flash on the display and the pump will continue
to operate for 15 seconds to allow the heater to cool off
before stopping.
All functions will turn off, but the pump low speed can be
activated (by pressing the
pad) to facilitate draining
the hot tub - the display will show
DN.
Press any pad other than the
pad to return the system
to normal operation.
See DRAINING YOUR HOT TUB for detailed instructions.