6 Screw Conveyor
It is recommended that the sensor is installed at 30° above the base (See Figure 6).
30°
150-300mm
Sampling Point
Figure 6: Screw Conveyor Installation
It is essential that the sensor is located so that the ceramic disc is continuously covered by at
least 100mm of material (Figure 7).
100
mm
100
mm
Figure 7: Screw Conveyor Material Level
7 Integration of Hydro-Mix HT in Ducting
The Hydro-Mix HT can be integrated into ducting. Modifications to the ducting might be required
to achieve consistent results.
Hydronix recommends the use of the Hydronix Ducting System (DSVHT or DSAHT) when
installing the Hydro-Mix HT into ducting (Figure 8). The systems are designed for use in vertical
(DSVHT) or angled ducting (DSAHT). Contact Hydronix for further details about the available
ducting systems.
Figure 8: Hydronix Ducting Systems (DSAHT and DSVHT)
Содержание Hydro-Mix HT
Страница 4: ...4 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 6: ...6 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 8: ...8 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 10: ...10 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 24: ...Chapter 1 Hydro Mix HT Installation 24 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 28: ...Chapter 3 Corrosion Protection 28 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 32: ...Appendix A Document Cross Reference 32 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...