14 Hydro-Mix HT Mechanical Installation Guide HD0766 Rev 1.2.0
5 Organic Material Mixers
When installing in a mixer it is important that the end wall scraper arm is adjusted to ensure that
the Ceramic Disc is kept clean to avoid material build up. A build-up of material on the end wall
will indicate that the scraper arm is not correctly adjusted and this will affect the sensor reading.
5.1
Twin Shaft
It is recommended that the Hydro-Mix HT should be located in the end wall between the two
shafts. The sensor should be located at a level lower than the shafts to maintain complete
coverage of the ceramic disc.
Figure 4: Twin Shaft Organic Mixer Installation
5.2
Single Shaft
Single shaft mixers should have the sensor installed in the end wall at 30° from the centre.
30.0°
Figure 5: Single Shaft Organic Mixer Installation
Содержание Hydro-Mix HT
Страница 4: ...4 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 6: ...6 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 8: ...8 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 10: ...10 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 24: ...Chapter 1 Hydro Mix HT Installation 24 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 28: ...Chapter 3 Corrosion Protection 28 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Страница 32: ...Appendix A Document Cross Reference 32 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...