5

Installing Float Switch
Controls:
The  controls  are  supported  by  a 
mounting  bracket  that  is  attached
to  sump  wall  or  cover  or  to  the
NEMA 4 junction box.

Cord  snubbers  are  used  to  hold 
the  cord  in  place.  Control  lever
can  be  changed  at  any  time 
by  loosening  the  snubber  and 
readjusting cord length.

In either simplex or duplex system
the  lower  or  turn-off  control  is 
set  just  above  the  top  of  volute 
so  that  the  volute  will  always  be
submerged  during  the  pumping
cycle.  The  second  or  turn-on 
control  is  set  about  24  inches
above the lower turn-off control. 

More  distance  between  turn-on
and turn-off controls can be used,
but  sewage  may  become  septic
and  excessive  solids  may  collect
for the pump to handle. A frequent
pumping  cycle  is  recommended
for best operation.

If  an  alarm  system  is  used,  this
control is usually set about 6 inches
above the override control.

Some  engineers  as  described 
previously  prefer  to  have  the
alarm  control  set  below  the 
override control.

Making Electrical Connections:
ALL  ELECTRICAL  WIRING
MUST  BE  IN  ACCORDANCE
WITH 

LOCAL 

CODE, 

AND 

ONLY 

COMPETENT 

ELECTRICIANS 

SHOULD

MAKE  THE  INSTALLATIONS.
Complete  wiring  diagrams  are
glued  to  the  inside  cover  of  the
panel,  and  an  additional  set  of
prints  is  included  for  use  in 
making  the  installation. All  wires
should  be  checked  for  grounds
with an ohmmeter or Megger after
the connections are made. 

this is

important,  as  one  grounded  wire

Pump
Operations

can  cause  considerable  trouble.
(See Fig. 1.)

IMPORTANT:  If  equipment  is
not properly wired and protected
as  recommended,  the  motor
guarantee is void.

NOTE: For wiring diagram for
wye  delta  see  Addendum
S4LRC-701.

Heat Sensors and Seal Failure
Connections:
Be  sure  that  heat  sensor  wires 
are  connected  in  series  with 
the  starter  coil.  Connections  are 
provided on the terminal strip; see
wiring diagram.

If seal failure unit is used, connect
as shown with seal failure system.
If seal failure unit is not used, the
two  seal  failure  wires  are  left
open. 

Do  not  connect

power  to  these  lines  at
any time. 
(See Figures 2 and 3.)

Starting System:
1.  Turn  H-O-A  switch  to  Off

position, then  turn  on  main
circuit breakers.

2.  Open  all  discharge  valves  and

allow water to rise in sump pump.

3.  Turn  H-O-A  switch  to  Hand

position  on  one  pump  and
notice  operation.  If  pump  is
noisy  and  vibrates,  rotation  is
wrong.  To  change  rotation 
interchange  any  two  line 
leads to motor on 3ø only. DO
NOT INTERCHANGE MAIN 
INCOMING LINES. If duplex 
system, check second pump in
the same manner. 

4.  Now  set  both  H-O-A  switches

to  Auto  position  and  allow
water to rise in sump until one
pump  starts.  Allow  pump  to
operate  until  the  level  drops
to turn-off point.

5.  Allow  sump  level  to  rise  to

start  other  pump.  Notice  run
lights  on  panel;  pumps  should

WARNING

BLACK

COIL

ON-OFF

SWITCH

L1

THERMOSTATS

IN SERIES

WHITE

L2

TWO WIRE CONTROL OFFERING AUTOMATIC RESET

THERMOSTATS

IN SERIES

WHITE

L2

BLACK

THREE WIRE CONTROL OFFERING AUTOMATIC RESET

L1

COIL

OL

OL

START

IN CERTAIN APPLICATIONS THE NEC MAY REQUIRE THREE OVERLOAD RELAYS

COLOR

PURPOSE

DARK GREEN SEAL FAILURE

RED

SEAL FAILURE

BLACK

HEAT SENSOR

WHITE

HEAT SENSOR

WARRANTY IS VOID IF HEAT SENSORS ARE NOT

CONNECTED AS SHOWN (IN SERIES WITH CONTACTOR OIL)

DESIGNATION FOR OPTIONAL

SEAL FAILURE & SENSOR CORD

See Wiring Diagram of seal failure

unit #4673 or 4674 for connecting

dark green and red wires. If seal fail-

ure unit #4673 or 4674 is not used,

leave dark green and red wires open.

Fig. 3

Содержание S4LRC

Страница 1: ...03 315 Part 5625 315 1 2011 Pentair Pump Group Inc NOTE To the installer Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system Installation and Service Manual For use with product built with GE motor ...

Страница 2: ...connected in series with the motor starter coil so that the starter is tripped if heat sensor opens The motor starter is equipped with 3 leg overload heaters so all normal overloads are protected by the starter IMPORTANT If Hydromatic electrical starting equipment is not supplied the heat sensor circuit must be connected in series with the starter coil or warranty on motor is void Connection diagr...

Страница 3: ...low inflow capacity Electrical Control Panel It is recommended that the Hydromatic control panel be used with all pumps as proper starter heaters and connections for heat sensor wires are furnished IMPORTANT If Hydromatic electrical controls are not used and the motor fails because of improper components or if the heat sensors are not properly connected the motor guarantee is void Hydromatic elect...

Страница 4: ...etimes installed without a check valve where it is desirable to self drain the discharge line to prevent freezing This can be done only with short discharge lines otherwise water will return to the sump and cause short cycling of the pump NEMA 4 Junction Box Optional If electrical control panel is to be set remote from the pump sump a NEMA 4 junction box should be used to make power and control co...

Страница 5: ...a see Addendum S4LRC 701 Heat Sensors and Seal Failure Connections Be sure that heat sensor wires are connected in series with the starter coil Connections are provided on the terminal strip see wiring diagram If seal failure unit is used connect as shown with seal failure system If seal failure unit is not used the two seal failure wires are left open Do not connect power to these lines at any ti...

Страница 6: ...ightning occurs it is recommended that a lightning arrestor be installed at the control panel Complete data on lightning arrestors and cost are available from the factory Lightning arrestors are good insurance against damage to an expensive motor Servicing Instructions WARNINg Before handling these pumps and controls always disconnect the power first Do not smoke or use sparkable electrical device...

Страница 7: ... into the stator This holding spot is drilled through the bolt hole when the stator is bolted in place with the end ring 11 Replace stator housing onto seal chamber and bolt in place BE SURE SEAL FAILURE WIRE IS CONNECTED BEFORE HOUSINg IS ASSEMBLED Be sure back off screws have been loosened so that parts can come metal to metal Be sure O ring seal has been replaced If O ring is nicked or cut repl...

Страница 8: ...Megger for grounds before operating the pump Below is a list of common problems and the probable causes WARNINg Before handling pumps and controls always disconnect power first Do not smoke or use sparkable electrical devices or flame in a septic gaseous or possible septic sump Pump will not start 1 No power to the motor Check for blown fuse or open circuit breaker 2 Selector switch may be in the ...

Страница 9: ...be installed on pump side of all valves Multiply gauge pressure in pounds by 2 31 to get head in feet 5 If pump has been in service for some time and capacity falls off remove pump and check for wear or clogged impeller Motor stops and then restarts after short period but overload heaters in starter do not trip 1 This indicates heat sensors in the motor are tripping due to excessive heat Impeller ...

Страница 10: ...o 20 HP 575 3 60 1750 RPM VFD Stator 1 RTF Stator 25 to 35 HP 230 460 3 60 1750 RPM VFD Stator 1 RTF Stator 25 to 35 HP 575 3 60 1750 RPM VFD Stator 1 47 RTF Rotor Shaft 2 to 5 HP 870 RPM 1 RTF Rotor Shaft 3 to 15 HP 1150 RPM 1 Ref Part Part No No Description Qty RTF Rotor Shaft 10 to 20 HP 1750 RPM 1 RTF Rotor Shaft 25 to 35 HP 1750 RPM 1 48 06000 003 5 Wire TerminalAssy Priorto5 1 78 1 06000 021...

Страница 11: ...11 S4LRC 55 56 54 3 53 52 50 51 49 48 47 46 45 41 42 40 35 36 38 31 33 30 37 34 28 27 26 20 2 4 5 6 7 60 8 57 9 11 12 13 14 15 16 18 19 1 29 58 ...

Страница 12: ..._____________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ __________...

Страница 13: ...__________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ ______________________________________________ _____________...

Страница 14: ...rdance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such service d to units which are not installed in accordance with applicable local codes ordinances and good trade practices e if the unit is moved from its original installation location f if unit is used for purposes other tha...

Страница 15: ......

Страница 16: ...g Line Voltage _________________________________Actual ___________________________________ Voltage to Pumps _____________________________________Actual ___________________________________ Type of Junction Box __________________________________Manufacturer of Junction Box ______________ Are Floats Installed in Wet Well Yes No Are Floats Set to Engineer s Specs Yes No Are Floats Wired for Proper Seq...

Отзывы: