Pump

Installation

Electrical Connections:

Make all connections from motor
to  control  panel  to  comply  with
local codes.

CAUTION:    Make  sure  that
the  ground  wire  is  securely
connected  and  that  the  unit 
is 

properly 

grounded 

in 

accordance with local codes.

Unpacking Pump:

Remove pump from carton. When
unpacking 

unit, 

check 

for

concealed  damage.  Claims  for
damage  must  be  made  at  the
receiving end through the delivery
carrier.  Damage  cannot  be
processed from the factory.

Installing Pump in Sump:

Before  installing  pump  in  sump,
lay  it  on  its  side  and  rotate
impeller. Impeller may be slightly

stuck due to factory test water so
it  must  be  broken  loose  with  a
small  bar  or  screwdriver  in  edge
of vanes. The impeller should turn
freely.  Do  not  connect  the  power
until after this test.
Clean  all  trash  and  sticks  from
sump and connect pump to piping.
A check  valve  must  be  installed
on each pump.

Location:

If  pumps  are  installed  in  an 
existing  basin  or  concrete  sump,
the piping can either be connected
permanently or rails and brackets
can  be  furnished  for  mounting  to
walls  of  basin.  In  either  case, 
be  sure  the  HYDROMATIC 
non-clog  ball  check  valve  is 
used  and  that  the  pumps  are 
submerged  in  a  vertical  position.
The 

complete 

factory-built 

packaged system is recommended
for 

the 

most 

satisfactory 

installation  and  generally  for  the
lowest  cost  where  expensive
installation labor is involved.

Making Electrical Connections:

All  electrical  wiring  must  be  in
accordance  with  local  code,  and
only  qualified  electricians  should
make  the  installations.  Complete
wiring  diagrams  are  included 
for use in making the installation.
All  wires  should  be  checked 
for  shorts  to  ground  with  an 
ohmmeter  or  Meggar  after  the
connections  are  made.  This  is
important,  as  one  grounded  wire
can cause considerable trouble.

IMPORTANT:  If  equipment  is
not 

properly 

wired 

and 

protected  as  recommended,
HYDROMATIC 

warranty 

is void.

Power Cords:

The  power  cord  and  heat  sensor
seal  failure  cord  are  potted  into
the connection box cap. The cords
must not be spliced.

NOTE:  Each  cable  has  a  green
lead.  This  is  the  ground  wire
and must be grounded properly
per N.E.C.  and/or local  codes.
During  normal  maintenance
procedures  power cords  should
be inspected for abnormal wear
and replaced accordingly.

Overload Heaters:

If  the  HYDROMATIC  electrical
panel  is  not  used,  starters  with 
3-leg  overload  relay  must  be 
supplied on 3-phase pumps. Each
leg  is  to  have  an  identical  heater
sized  in  accordance  with  the
nameplate  amps  on  the  motor
housing.  The  amp  draw  on  these
submersible  motors  is  slightly
higher  than  a  corresponding
horsepower  surface  motor,  so
heaters  must  be  sized  by  the
nameplate rating.
Single-phase pumps with capacitor
start  have  a  run  and  a  start 
winding, 

each 

drawing 

different  current.  To  adequately
protect  these  windings  with 
the  appropriate  heaters,  consult
the factory.

NOTE:  Red  lead  is  always 
start  winding  of  pump  using
single phase.

WHITE W/BLACK STRIP - P1

BLUE - P2

ORANGE - SEAL PROBE

SENSOR LEADS

208 - 230V SINGLE PHASE

T4

T5

T8

BLACK

L2

WHITE

L1

RED

L3

P1 (PURPLE)

P2 (BROWN)

MOTOR LEADS

230V (DUAL VOLTAGE) THREE PHASE

P1 (PURPLE)
P2 (DARK BROWN)

T7

T8

T9

T1

T2

T3

T4

T5

T6

BLACK

L2

WHITE

L1

RED

L3

200V AND 575V THREE PHASE

T1

T2

T3

BLACK

L2

WHITE

L1

RED

L3

P1 (PURPLE)

P2 (BROWN)

460V (DUAL VOLTAGE) THREE PHASE

PL (PURPLE)
P2 (DARK BROWN)

T7

T8

T9

T1

T2

T3

T4

T5

T6

BLACK

L2

WHITE

L1

RED

L3

Содержание HPGLX200

Страница 1: ...ure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system Explosion Proof Submersible Grinder Pumps Class I Division 1 Group C D FM HPGX200...

Страница 2: ...ble concealed shipping damage Any damage should be reported immediately to delivery carrier Claims for damage must originate at the receiving end Claims for shipping damage cannot be processed at the...

Страница 3: ...for use in making the installation All wires should be checked for shorts to ground with an ohmmeter or Meggar after the connections are made This is important as one grounded wire can cause considera...

Страница 4: ...s necessary 2 Run water into sump until motor is covered 3 Open gate valve in discharge line 4 Turn pump on If pump runs and sump liquid does not pump down stop pump and close discharge gate valve The...

Страница 5: ...rts can now be cleaned without removing them from the shaft 7 If necessary to replace cutters remove hex head screw 19 washer 20 and radial cutter 40 from shaft Radial cutter 40 and impeller 17 are sc...

Страница 6: ...e wire connections and then remove the power cable 4 Turn the motor housing over and remove the stator bolts 29 from the stator 31 then remove the stator from the motor housing 33 5 Place new stator 3...

Страница 7: ...or piping plugged 4 Wrong rotation 5 Speed too low Insufficient liquid delivered 1 Discharge head too high 2 Impeller or cutters partially plugged or damaged 3 Wrong rotation 4 Incorrect diameter imp...

Страница 8: ...Stator 2HP 230 1 60 1 10832 203 1 Stator 2HP 200 1 60 1 32 10823 101 5 Rotor Shaft Assy 2HP 3f 1 10832 101 5 Rotor Shaft Assy 2HP 1f 1 33 13494 004 2 Motor Housing 1 34 00065 001 1 Upper Bearing R 1...

Страница 9: ...4 14 15 15 13 13 26 26 28 28 16 16 39 39 18 18 17 17 42 42 40 40 41 41 19 19 20 20 27 27 22 22 7 21 21 6 24 24 25 25 23 23 11 11 12 12 9 10 10 5 3 4 1 38 38 36 36 29 29 32 32 30 30 31 31 34 34 35 35 3...

Страница 10: ...or 2HP 200 3 60 1 10823 603 1 Stator 2HP 575 3 60 1 10832 003 1 Stator 2HP 230 1 60 1 10832 203 1 Stator 2HP 200 1 60 1 32 10823 101 5 Rotor Shaft Assy 2HP 3f 1 10832 101 5 Rotor Shaft Assy 2HP 1f 1 3...

Страница 11: ...15 13 13 26 26 28 28 16 16 39 39 18 18 17 17 42 42 40 40 41 41 19 19 20 20 27 27 22 22 7 21 21 6 24 24 25 25 23 23 11 11 12 12 9 10 10 5 3 4 1 38 38 36 36 29 29 32 32 30 30 31 31 34 34 35 35 33 33 2 3...

Страница 12: ...on Any transportation charges involved in such disposition shall be for the Buyer s account The Buyer s exclusive and sole remedy on account or in respect of the furnishing of material that does not c...

Отзывы: