HydroMassage Owner’s Manual, Revision 10-25-15
JTL Enterprises, Inc 1-727-536-5566 • www.HydroMassage.com
Page 8 of 33
HydroMassage
®
Installation Preparation Instructions
Room Preparation
Determine where the unit will be located. The minimum room size is 8’ x 6’. To maximize user comfort an
8’ x 10’ or larger is preferred. For best results with the Series 320/350/500/700 Series (with external cooling
system), it is recommended that cooling system is installed in a separate area or vented to remove heat from
room – see “External Cooling System Heat Exhaust Vent” section.
Electrical Requirements
Series 440-450 Lounge
•
A dedicated line supplying a voltage within the range of 208-volt to 240-volt power.
•
30-amp dedicated breaker
•
Requires 10 gauge wire (2 hot legs and a ground
*
) USA / 4 mm wire internationally
•
Equipment is
shipped with a NEMA L6-30 Locking Receptacle (shown below- 3 prong plug)
/ For
International installations: please have your electrician install an appropriate plug and receptacle
according to code
•
Requires a 110 Volt outlet within 5’ of the center of the HydroMassage Lounge.
•
CAT 5 or Cat 6 Internet / Network connection at least 6’ from Lounge
Please be sure your electrical installation is completed before the unit arrives
.
*If the equipment will be installed in a patient care area, additional electrical requirements may apply.
Water Requirements
Distilled water contains no chlorine and is free of minerals and other chemicals that can cause build-up and
decrease the life expectancy of key components. Distilled water is available at most major supermarkets or
directly from your water supplier (if you have a water delivery service). Please have water on hand the day of
installation.
•
Series 440-450:
•
Add 20 gallons
Specifications
Dimensions: 80” (239cm) long, 32” (95cm) wide, 43” (69cm) high
Weight: 285lbs (130kg) without water. 405lbs (184kg) with 20 gallons (60L) of distilled water.
Requires a doorway larger than 29” to install in room.
NEMA L6-30R
Locking Receptacle
(USA Only)
X
Y
G