HydroMassage Owner’s Manual, Revision 10-25-15
JTL Enterprises, Inc 1-727-536-5566 • www.HydroMassage.com
Page 24 of 33
HydroMassage
®
Final Assembly
1) Position HydroMassage unit in final location (centered on wall)
•
For all models, allow for a minimum of 3’ of excess electrical and cooling system wiring to enable
movement of HydroMassage unit during servicing or maintenance.
•
Secure water lines and power cord together. Give water line enough slack to ensure when cord is
moved, the water lines do not bend at cooling system connections.
•
For 440 Series models (with internal cooling systems), ensure 12” of clearance from wall at head end of
unit for proper airflow.
•
Complete one last visual inspection under the Lounge to confirm no water has dripped on the flooring
2) Re-attach end panels (first) and side panels (second)
3) Install Side and End panels. Fasten side panels securely with end-panel knobs/screws
4) Re-attach comfort pad (first) and top cover sheet (second)
•
When attaching the comfort pad, begin with the snap at the head-end, and work your way around the
Lounge until entire pad is attached to the panels.
•
The nylon cover sheet will attach to the comfort pad with snap connections. There is an opening on the
side for the Touchscreen Mount.
5) Contact HydroMassage Technical Support Department at 727-536-5566 to install HydroMassage
Desktop Software and Remote Access Software ( if applicable)
Screws to
attach
panels
Comfort
pad
snaps
Excess
wiring coiled
neatly and
zip-tied to
give slack
when moved