TROUBLESHOOTING, CONT.
Q: Why is the system leaking?
A: This can be due to various reasons, including lack of Teflon tape at threaded
fittings, tubing not being pushed in all the way to the quick connect fittings, or
improperly seated O-rings in pre-filter and membrane housings. It is also important
to make sure the ends of the tubing have a clean cut before inserting them into the
quick connect fittings (see pg. 11) Please call us if you’re experiencing any leaks.
Q: Why did the clear pre-filter housing crack?
A: This can be due to freezing conditions, excessive pressure spikes, or long-term
exposure to high intensity lighting. Replacement housings are available.
Q: Why is the pH of the purified water higher/lower than the source water?
A: The pH of the purified water depends entirely on source water chemistry.
Customers can experience either slightly lower or higher pH after filtration. This is
completely normal for Reverse Osmosis technology. Since RO water is almost pure
H
2
O and has no ability to buffer pH, the actual pH reading will not be accurate until
you add minerals back.
Q: Why are both the
1:1
and
2:1
Flow Restrictors included in the box?
A: The Flow Restrictor(s) determines your waste to purified water ratio. HydroLogic
has always provided two options for the waste to purified water ratio, because water
conditions vary across the world; one fixed ratio would not work for every water
condition. Please see pg. 7 for more detailed information.