10
Be sure the Flow Restrictor/Flush Kit Assembly’s blue valve is open (handle is parallel with tubing,
see figure
E
). Next, slowly turn the source water on until both the Carbon and Sediment filters have
water in the housings. Once both pre-filter housings are full, open source water up all the way (do
not exceed 80 psi). Power flush the system for 2–3 minutes when the system is new and/or when you
replace your carbon filter. Next, close the blue valve and continue to flush the membrane for 30–45
minutes. This will flush out the food grade preservative in the membrane.
After the initial 30–45 minute flush, turn the inline shut-off valve (pre-installed on the blue purified
water line) to the off position (perpendicular to the tubing). This will shut the water off on both the blue
and black lines, and pressurize the system. This is a good way to make sure that all the fittings and
connections are secured properly and that there are no leaks. It is also a good way to make sure that
the ASOV is working properly, meaning the black drain line is also shutting off shortly after the blue
line shuts off. If there are problems of any kind please contact HydroLogic directly at 888-426-5644
Note:
It may take up to 24 hours of running the system for the PPM of the purified
water to stabilize
at the lowest rejectiion reading.
WARNING: USING NON-ORIGINAL
REPLACEMENT FILTERS OR MEMBRANES
WILL VOID THE WARRANTY
STEALTH-RO150 SETUP, CONT.
E
This is only open during a new filter flush, and
always closed during normal operations
ASOV