INSTRUCTIONS
NAVIGATION AND MENU STRUCTURE
The PX1 has a four-line green display controlled by a five button navigation control (Up/Down/Next/
Page/Enter). Menu items are listed in the table below. There are four menu pages: a status display
page (the default display when the PX1 is powered up); the Zone A settings page; the Zone B settings
page; and the date/time page.
Menu
Element
Values
SET
Date
MMDDYY
Time
HHMM
Time Format
12/24
Temp Units
C/F
Output Units
%/W
ZONE A
Set Output
See Reference Chart on page 5
Ballast Type
400/600/750/1000
Lights On
HHMM
Lights Off
HHMM
Sunrise/Sunset OFF/5/10/15/20/30 Min
Overtemp Dim
Limit
68°F-105°F
Overtemp
Shutdown Limit 85°F-140°F
Hot Start Delay OFF/5/10/15/20/30 Min
ZONE B
Set Output
See Reference Chart on page 5
Ballast Type
400/600/750/1000
Lights On
HHMM
Lights Off
HHMM
Sunrise/Sunset OFF/5/10/15/20/30 Min
Overtemp Dim
Limit
68°F-105°F
Overtemp
Shutdown Limit 85°F-140°F
Hot Start Delay OFF/5/10/15/20/30 Min
The menu is designed to be simple and easy to navigate. Page
moves from page to page; Next
moves from field to field, Up
and Down
make changes. Enter
saves the data. (If you make
a change but then decide not to enter it, simply press Page to go to another page without saving.)
A blinking underline indicates the cursor position. Each menu screen times out after 20 seconds of
inactivity bringing the PX1 back to the Status Display Page.