background image

Troubleshooting Guide

 

 

 

 

 

Sleeve Bypass Caps are provided should you have a problem (ie. breakage or a 
leak). The Caps may be put in place of a Sleeve so that you can still run your 
system until you receive replacement parts (See Figure 7). 

 

To remove a Sleeve or a Bypass Cap from the Manifolds, first release pressure by 
both opening a faucet and shutting off water at the house water supply shutoff 
valve. Push the Sleeve or Bypass Caps further onto the Manifold to set the 
disconnect fittings back into place. The disconnect fittings are part of the elbows. 
Put your thumbs on the Sleeve or Bypass Caps, press your thumbs towards the 
wall, wrap your fingers around the copper, and slide them towards your thumb 
which will pull the disconnect fitting into the elbow. Finally, pull the Sleeve or 
Bypass Caps off the Manifold. To remove a Sleeve, you must pull both sides at 
once. A Disconnect Clip has been provided should you need assistance (Figure 8). 

If your system leaks at fittings: Release pressure by both opening a faucet and    

 

 

 

 

 

 
 
 
 
 
 
 

 
 

Remove Sleeve and check for burrs and/or dirt. Ensure the elbows are aligned and add additional

 

silicone to ensure a water tight seal. 

After time, If you notice a bad taste or odor, this indicates that the media in the Media is                               
saturated, and needs to be changed. It is recommended to change every 6 months. 

 

You can order your refills at 

www.hydrocareusa.com

. Save 10% on auto refill subscription.

 

Contact : HydroCare USA  888 967 9283  or emai

[email protected]

. 

 

Quadmaxx® is tested and certified by WQA to NSF/ANSI 61 for materials safety only. 

 

Quadmaxx® assembled in U.S.A 

 

 

Содержание Quadmaxx

Страница 1: ...Installation Use and Care Manual ...

Страница 2: ...er flow The system should be located after connection for the outside hose bibs sprinkler system s and or irrigation line s These lines should be left untreated Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Install in a location that is not susceptible to freezing temperatures as damage to the Sleeves could occ...

Страница 3: ... pieces into the Sleeve as you go Place the thick micron pad next to the last black piece The thin pad goes in last 3 Thread the Outlet End Cap back into place Repeat for each Sleeve from step 5 4 Use remaining Silicone Grease to coat the outsides of the copper inlets and outlets 5 Make sure each Sleeve is squared up Put each Sleeve on a flat service and look to see that the elbows line up with ea...

Страница 4: ... the Media is lined up correctly with the direction of your water flow push each Sleeve onto the Manifold one at time sliding each elbow of the Sleeve on simultaneously Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Connection Instructions 1 Installation of a water shut off valve at the unit is recommended for media replacement changes and for emergency shut off water 2 Turn off your water ...

Страница 5: ...your thumb which will pull the disconnect fitting into the elbow Finally pull the Sleeve or Bypass Caps off the Manifold To remove a Sleeve you must pull both sides at once A Disconnect Clip has been provided should you need assistance Figure 8 If your system leaks at fittings Release pressure by both opening a faucet and Remove Sleeve and check for burrs and or dirt Ensure the elbows are aligned ...

Отзывы: