background image

 

 

10.

 

Remove all (8) plastic red caps from the ends of the Sleeves (Shown in Figure 4). They can be discarded. 

11.

 

To ensure that both the inside of each elbow and the outside of the Manifolds are properly coated  
with Silicone Grease, put the Sleeve on the Manifold one end at a time (See Figures 5 & 6). Remove  
each end and put it back on 2 or 3 times. If needed, see Troubleshooting Guide on the following page             
for instructions on removing the Sleeve. 

12.

 

The elbows on each Sleeve are aligned when lines painted on each Sleeve match up by tightening  
or loosening each end cap (See Figures 3 & 4). Make sure each Sleeve sits on a flat surface without  
rocking. (See bottom of Figure  1). 

13.

 

Using the arrows on the Sleeves to ensure the Media is lined up correctly with the direction of your water 
flow, push each Sleeve onto the Manifold one at time sliding each elbow of the Sleeve on simultaneously. 

Figure 1 

Figure 2 

Figure 3 

 

Figure 4 

Figure 5 

Figure 6 

Connection Instructions

 

 

1.

 

Installation of a water shut off valve at the unit is recommended for media replacement changes and  
for emergency shut off water. 

2.

 

Turn off your water supply. Turning off your water heater is recommended. 

3.

 

Release water pressure by opening faucet. 

4.

 

Attach water source to Manifold Inlet. Existing Inlet or 

outlet pipe size smaller or greater than 1” will require 

an additional adapter. 

5.

 

You may now turn your water on. Go slowly and check for leaks. Run water for 10 minutes or until  
all gray or cloudy water is gone.  You may get an occasional gray burst during the first 48 hours. The  
water is safe to drink. Turn your water heater on. 

 

Figure 7   

 

 

 

 

Figure 8 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open 

Side 

Содержание Quadmaxx

Страница 1: ...Installation Use and Care Manual ...

Страница 2: ...er flow The system should be located after connection for the outside hose bibs sprinkler system s and or irrigation line s These lines should be left untreated Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Install in a location that is not susceptible to freezing temperatures as damage to the Sleeves could occ...

Страница 3: ... pieces into the Sleeve as you go Place the thick micron pad next to the last black piece The thin pad goes in last 3 Thread the Outlet End Cap back into place Repeat for each Sleeve from step 5 4 Use remaining Silicone Grease to coat the outsides of the copper inlets and outlets 5 Make sure each Sleeve is squared up Put each Sleeve on a flat service and look to see that the elbows line up with ea...

Страница 4: ... the Media is lined up correctly with the direction of your water flow push each Sleeve onto the Manifold one at time sliding each elbow of the Sleeve on simultaneously Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Connection Instructions 1 Installation of a water shut off valve at the unit is recommended for media replacement changes and for emergency shut off water 2 Turn off your water ...

Страница 5: ...your thumb which will pull the disconnect fitting into the elbow Finally pull the Sleeve or Bypass Caps off the Manifold To remove a Sleeve you must pull both sides at once A Disconnect Clip has been provided should you need assistance Figure 8 If your system leaks at fittings Release pressure by both opening a faucet and Remove Sleeve and check for burrs and or dirt Ensure the elbows are aligned ...

Отзывы: