Use your Bracket, level and pencil to locate and mark your 2 wall mount locations. Remove the Housing Lids from the
Housings and line up the Lids putting the HC-DP-PRE (Pre-Filter) on the inlet side and the set of HC-DP-CRLD filters on
the outlet side. The pressure release button on the HC-DP-PRE will be in the back where the Inlet will be. The pressure
red release buttons for the HC-DP-CRLD filters will be in the front where the Outlet Supply Assembly will be connected.
The system can be set up left to right or right to left depending on the direction of the water’s flow path. See Figures
below.
Installation Instructions
Use the Teflon® Tape provided to wrap each end of the five Connectors in a clockwise
direction overlapping the tape 5 to 6 times.
Thread 3 Connectors into each of the Housing Lid outlets and 2 Connectors into the inlets of the HC-DP-CRLD Lids. by
hand. Use adjustable wrench until each Connector is tight. Push in your Inlet Supply Assembly into the 3 Connectors in
front. Push in your Outlet Supply Assembly into the 2 Connectors in back. Mount the Housing Lids to the Bracket with
the lag bolts provided. Mount the Bracket to your marked locations using the wall mount screws provided.
Left to right water flow path
Right to left water flow path
Mount the Housing Lids to the Bracket with the lag bolts provided.
Left to right water flow path
Right to left water flow path
Pre-Filter
Pre-Filter