WARRANTY 

– SAFETY WARNINGS   

 

 

 

 
GENERAL 

CONDITIONS

 

Hydro 

Tek’s 

responsibility  with  respect  to  claims  is  limited  to 
making the required repairs or replacements to the 
original  retail  user,  and  no  claim  of  breach  of 
warranty  shall  be  cause  for  any  cancellation  or 
rescission of the contract of sale of any Hydro Tek 
product.  Hydro Tek reserves the right to change or 
improve  the  design  of  any  of  its  products  or 
illustrations  without  assuming  any  obligation  to 
modify any product previously manufactured. 
This  supersedes  any  and  all  previous  warranty 
statements  for  products  purchased  after  March  1, 
2009.  Hydro Tek is not liable for indirect, incidental 
or  consequential  damages  including  any  cost  of 
substitute  equipment,  loss  of  revenue,  pecuniary 
expense  or  loss,  or  inability  to  use  a  Hydro  Tek 
product.    Hydro  Tek  disclaims  all  implied 
warranties,  including  those  of  merchantability  and 
fitness  for  use  for  a  particular  purpose.    Some 
states do not allow exclusions or limitations on how 
long  an  implied  warranty  lasts,  so  the  above 
exclusions may  not  apply  to  you.    It  is  the  buyer’s 
responsibility  to  ensure  installation  and  use  of 
Hydro  Tek  products  conforms  to  local  codes.  
Products exported outside the US and Canada are 
covered  solely  by  the  warranty  of  the  local  export 
dealer and this warranty does not apply. 
 

HOW TO OBTAIN WARRANTY SERVICE: 

1.  List washer model#______________________.  
List serial #____________________ (on base plate 
of machine near the motor). 
2.  Contact your local service dealer and return the 
Hydro  Tek  washer  or  part  within  the  warranty 
period  along  with  your  sales  receipt.    To  locate 
service,  call  Hydro  Tek  and  ask  for  technical 
services or go to: www.hydrotek.us 
3.  You  also  have  the  option  to  obtain  a  return 
goods authorization and ship the questionable part 
freight prepaid directly to the factory.  The part will 
be  evaluated  upon  receipt.    If  found  defective, 
Hydro  Tek  will  repair  or  replace  part  under  the 
conditions of warranty and return to you. 
4.  If  the  defective  component  is  an  engine  or 
motor  made  by  another  manufacturer,  we,  or  your 
authorized  Hydro  Tek  dealer,  can  help  you  obtain 
warranty 

service 

through 

the 

specific 

manufacturer’s local authorized service center. 
5.  If you are unable to resolve the warranty claim, 
write to Hydro Tek Systems, Inc. 2353 Almond Ave. 
Redlands,  CA  92374,  Attn.:  Technical  Services.  
Please  enclose  a  copy  of  the  dated  purchase 
receipt and explain the nature of the defect. 
 

 

 
 
ELECTRICAL PRECAUTIONS: 

1. 

Observe all State, Local, and National codes 

for  the  installation  of  your  electrically  powered 
washer.

 

2.  For  a  grounded  product  rated  250  volts,  single 
phase,  or  less:    This  product  is  provided  with  a 
ground  fault  circuit  interrupter  built  into  the  power 
cord  plug.    (7.5hp  single  phase  excluded;  order 
GFCI separately). If replacement of the plug or cord 
is needed, use only identical replacement parts. 
3.  GROUNDING INSTRUCTIONS: 
Cord Connected, Grounded Products: 
This  product  must  be  grounded.    If  it  should 
malfunction,  grounding  provides  a  path  of  least 
resistance  for  electric  current  to  reduce  the  risk  of 
electric shock.  The product is equipped with a cord 
having  an  equipment-grounding  conductor.    The 
plug must be plugged into an appropriate outlet that 
is  properly  installed  and  grounded  in  accordance 
with all local codes and ordinances. 
DANGER 

– Improper connection of the equipment-

grounding  conductor  can  result  in  a  risk  of 
electrocution.    Check  with  a  qualified  electrician  or 
service personnel if you are in doubt as to whether 
the outlet is properly grounded.  Do not modify the 
plug  provided  with  the  product,  do  not  cut  off  the 
ground pin 

– if it will not fit the outlet, have a proper 

outlet  installed  by  a  qualified  electrician.    Do  not 
use any type of adaptor with this product. 
4.  To  comply  with  the  national  electric  code,  this 
pressure  washer  should  only  be  connected  to  a 
receptacle that is protected by a ground fault circuit 
interrupter (GFCI). 
5.  EXTENSION  CORDS:    Use  of  extension  cords 
is not recommended. 
6.  NEVER operate an electrically powered washer 
after  it  has  tripped  a  breaker  or  a  ground  fault 
device  without  have  the  reason  for  the  trip 
determined  by  an  authorized  service  engineer  or 
competent electrician. 
7.  Use only in a dry area.  Do not handle electrical 
cords  and  plugs  when  they  are  wet,  when  your 
hands are wet, or when standing in water.   Do not 
spray high-pressure water on to the machine. 
8.  Disconnect  power  supply  before  making  any 
repairs or adjustments. 

WARNING 

THIS EQUIPMENT CAN BE HAZARDOUS TO THE OPERATORS 
SAFETY  AND  ONLY  AUTHORIZED  PERSONNEL  WHO  HAVE 
READ AND UNDERSTOOD THE OPERATON MANUAL SHOULD 
BE  PERMITTED  TO  OPERATE  THIS  UNIT.    NEVER  ALLOW 
CHILDREN TO PLAY ON OR AROUND THIS EQUIPMENT. 

Содержание HD series

Страница 1: ...S HP SERIES HX SERIES SS SERIES SC SERIES SCU SERIES IMPORTANT TO REDUCE RISK OR INJURY READ OPERATING INSTRUCTIONS CAREFULLY BEFORE USING Hydro Tek 04 2010 Easy Clean Systems 11337 Trade Center Drive 200 Rancho Cordova CA 95742 916 638 0828 800 292 EASY www EasyCleanSystems com ...

Страница 2: ...WASH WATER RECYCLE POWER WASHERS Cold Water Hot Water electric Self contained Skids Natural Gas Trailers HOSE REELS SURFACE CLEANERS ...

Страница 3: ...eating System 9 10 Coil Heat Exchanger System Diesel Fired Burner Pressure Delivery System 10 11 Discharge Hose Gun Wand Assembly Nozzles Accessories 11 12 Wet sandblaster turbo nozzle reels Hydro Twister Wastewater recovery TRAILERS 13 TROUBLESHOOTING GUIDE 14 15 BURNER TROUBLESHOOTING GUIDE 16 17 SERVICE MAINTENANCE INFORMATION 18 EXPLODED VIEW Enclosed TRAILER REGISTRATION CERTIFICATE OF ORIGIN...

Страница 4: ...r a local auto parts store Connect the battery cables and follow the operation instructions for starting Pressure Steamers are electric powered and will require an appropriate electric outlet or disconnect box and an electric plug that is rated for your machine s voltage and amperage and matches to your electrical socket Smaller machines are equipped with a ground fault interrupter on the electric...

Страница 5: ...warranty claim write to Hydro Tek Systems Inc 2353 Almond Ave Redlands CA 92374 Attn Technical Services Please enclose a copy of the dated purchase receipt and explain the nature of the defect ELECTRICAL PRECAUTIONS 1 Observe all State Local and National codes for the installation of your electrically powered washer 2 For a grounded product rated 250 volts single phase or less This product is prov...

Страница 6: ...ust vent at least 8 diameter to the outside through the van roof or though the side panel that is at least 10 in diameter and position this vent to avoid water dirt and debris collection No flammable liquids aerosols or flammable materials should be stored within 24 of the unit and should not be stored under the unit During refueling ALL ignition sources and switches should be OFF and there should...

Страница 7: ...ay gun until a constant stream of water comes out Purging works best with nozzle removed from wand and or dual wand in the low pressure mode 3 SELECT DESIRED NOZZLE Connect nozzle securely to spray wand If equipped close pressure adjusting knob on dual wand Hold gun firmly squeeze trigger for high pressure spray CAUTION Gun kicks back hold with both hands WARNING risk of explosion DO NOT spray fla...

Страница 8: ...g the broad spray nozzle works best to perform rinsing and delicate surface washing In areas where the cleaning is more difficult and in smaller areas such as cracks and holes use the narrow spray nozzles 0 or 15 degree Chemicals can be applied in a couple of different ways One way is with a hand spray pump The other is with the chemical system on the equipment either downstream or high pressure d...

Страница 9: ...g of 87 or higher in the engine fuel tank Do not use unapproved gasoline such as E20 or E85 ethanol blends Up to 15 MTBE methyl tertiary butyl ether or 10 ethanol is acceptable Any failures from use of these fuels will not be warranted Consult engine manual for proper oil type and capacity The engine manufacturer recommends a break in period of 25 hours at which time the engine oil and filter shou...

Страница 10: ...e is preset at the factory to govern the proper output pressure of your machine It will release the pressure of the pump back into the inlet if the trigger on the spray gun is released NEVER increase the set pressure on the unloader to exceed the specifications for your machine All hot water machines are equipped with a SAFETY PRESSURE RELIEF VALVE In the unlikely event that your unloader fails or...

Страница 11: ...cket around the outside of the heating area It is double wrapped with ceramic blanket insulation and a stainless steel cover The inside of the coil assembly can become covered with soot if the burner is out of adjustment or if it is fired by diesel fuel This can be cleaned by removing both end caps on the coil enclosure and brushing or spraying off debris or by adding a soot removal agent Part CB2...

Страница 12: ... stop when the trigger gun is released and is controlled through a high amperage contactor To help keep the battery fully charged and for safely cooling down the burner turn off the burner during the last minute of rinsing When leaving the machine unattended shut off burner and engine switch Replace 12 VDC battery regularly 2 year maximum interval on 12V burner systems to help ensure consistent pe...

Страница 13: ...igher temperature Up to 250 F The 40 nozzle spreads the water stream over a wide area to give you less impact for delicate surfaces OPTIONAL ACCESSORIES WET SANDBLASTER The wet sandblaster is a system that introduces sand or other media such as baking soda into the water stream for abrasive blasting It is especially effective for graffiti or paint removal Performance of the unit is directly relate...

Страница 14: ...ailable at Hydro Tek dealers HYDRO TWISTER Surface Cleaners The Hydro Twister is a flat surface cleaner that connects to a pressure washer and uses a spray bar rotating at a high speed within 1 of the ground It will clean concrete more consistent than an operator with a spray wand with less fatigue and 10 20 times faster Simply move the twister over the surface and watch a clean path appear behind...

Страница 15: ...n tires Check all bolts including the lug nuts for tightness and condition periodically Double check safely chain and wire harness before departing Check latch on coupler and adjust if required to fit your trailer ball properly Never tow without properly adjusted rear view mirrors brake actuators or lights Grease wheel bearings as required TRAILER MAINTENANCE SCHEDULE ITEM FUNCTION REQUIRED 3 MTH ...

Страница 16: ...m De scale coil for better water flow Remove spray nozzle and pull trigger to check auto start function Check mechanical function electrical signal to relay Pumping System Trigger gun leaks or will not shut off Debris in gun valve assembly Clean valve assembly or replace gun Pump runs but has low spray pressure Water turned off Nozzle is plugged or sized incorrectly Inlet chemical injection valve ...

Страница 17: ...k relieving water Excessive over pressurizing and system spikes Take in for system check Battery Battery keeps losing voltage For 12v systems Battery voltage low RPM too low Engine charging system faulty Electrodes misadjusted Fuel pump pressure too high Air band too far open Burner amp draw too high Have battery checked and load test charge if low and replace if necessary Allow water to cool 2 mi...

Страница 18: ...K BELT TENSION ADJUST IF NEEDED ADJUST ENGINE RPM TO RUN WITHIN SPEC VOLTAGE OUTPUT CHANGES WITH GENERATOR SPEED CHECK CAPACITOR FOR 16MFD ARC TERMINALS WITH SCREW DRIVER BEFORE TESTING IF ALL THESE TEST GOOD REPLACE GENERATOR NO DOES THE LIGHT ON THE BURNER SWITCH COME ON WHEN THE TRIGGER IS PULLED YES YES TURN THE THERMOSTAT FULLY CLOCKWISE CHECK FOR CONTINUITY REPLACE IF NO CONTINUITY CHECK FOR...

Страница 19: ...00 RPM FOR DIRECT DRIVE REPAIR CHARGING CIRCUIT AND OR REPLACE BATTERY IF NEEDED LOW VOLTAGE WILL AFFECT BURNER PERFORMANCE IS THERE FUEL VAPOR COMING OUT OF THE BURNER EXHAUST CHECK THE TRANSFORMER FOR SPARK CAUTION HIGH VOLTAGE CHECK ELECTRODE ADJUSTMENT AND AIR BAND ADJUSTMENT SEE BURNER SPEC SHEET FOR SETTING ELECTRODE GAP IMPORTANT CHECK ELECTRODES FOR CRACKS REPLACE FUEL NOZZLE REPLACE INSUL...

Страница 20: ...lug Maintenance 500 hours or 6 months Clean Fuel Tank s Annually Replace Fuel Lines Annually Pump Oil Inspect Daily Change After first 25 hours then every 6 months or 500 hours Axial pumps come filled with synthetic oil which does not require changing Clean Replace Burner Filter Monthly More often if fuel quality is poor Remove Burner Soot Annually Burner Adjustment Cleaning Annually De scale Coil...