Programming
Prime Pump “P-1”
Press the Scroll Key to select pump number. Press the Enter Key to turn pump on. Press the Enter Key
again to turn the pump off. Pump prime automatically ends after 5 minutes, if pump is left on.
Clear Load Counter “CLr”
Every two seconds, the screen alternates between CLr and load count (all formulas). Press and hold the
Enter key for two seconds to reset the Load Counter.
Operating Parameters “oP”
Every two seconds, the screen alternates between oP and the current selection. Press the Enter key to
select the desired mode of operation: Au (Automatic), Pb (Push Button), oc (Occurrence), or r (Relay).
NOTE
: The four operating modes, Lockout Period, and other related operational details are described in more
detail under Theory Of Operation.
Lockout Period “LP”
Press the Enter key to display/edit Lockout Period value in minutes. Input method is the same as Password
input. 00.0 = Lockout off. The range of adjustment is 00.0-99.9 minutes.
NOTE
: In Occurrence and Push Button Modes, the programmed Lockout Period must be longer than the total
time of all programmed pump run times and delay times. The Lockout Period should approximate the washer
cycle time for a complete load.
Formula Program “F-1”
Press Scroll key to select the formula number (1-4) you wish to program. Press the Enter Key to move to the
Program Formulas menu loop for the selected formula number. This menu loop is not available in Relay Mode.
If data is input in this loop and Relay Mode is later selected, all values will be retained for later use if Relay
Mode is cancelled. Use the Next key to step through all available menu screens in this loop.
Pump Amount “P1A”
Every two seconds, the screen alternates between the stored run time (in seconds) for the selected pump
number and Pxx. Press the Scroll key to select the desired pump number (P1A, P1B, P2A, P2B, and P3 are
the available pump numbers). To set a pump run time, press and hold the Enter key for two seconds to start
the pump (display will increment seconds and pump will run). When desired time/volume is reached, press
the Enter key again to stop the pump and set the value. Repeat for all desired pumps. The adjustment range
is 000-240 seconds.
Delay Time “D1A”
Press the Scroll key to select the pump number (P1A, P1B, P2A, P2B, and P3) to be delayed. Press the
Enter key and input delay time in the same manner as Password input. In Push Button Mode, program
Delay Times in minutes (display will read 00.0). In all other modes, Delay Times are seconds (display
will read 000).
Assign Pump “A1A” (only in Occurrence Mode)
Assigns pump numbers to signal sequence occurrences. At the A1A screen, press the Scroll key to select
the pump number (P1A, P1B, P2A, P2B, and P3) you wish to assign to a machine step occurrence. Press the
Enter key to access occurrence input screen (oc). Press the Scroll key to assign the previously selected pump
number to the machine step occurrence (1-9) in which you desire that pump to run. Press the Enter key to set
this assignment and return to the formula programming sub-menu loop. Repeat for all pumps/occurrences.
Finish Program “Fin”
Press the Enter key at this screen to return to the F-1 formula number selection screen in the main menu loop.