28
T2™
BYPASS ARM
Refer to Figure 21
Disassembly
1. Remove all external items previously dis-
cussed in their recommended order.
2. Remove the retaining ring (35) and discard.
Remove the bypass arm (34).
3. Remove the retaining ring (33) and dis-
card.
4. Remove the bypass rod (32) and the clip
retaining ring (31) as a single item.
NOTE:
It is not necessary to remove the clip
retaining ring (31) from the bypass rod
(32) unless it is damaged or worn.
5. Remove the lip seal (30) and discard.
Inspection
1. Inspect the bypass rod (32) for wear or dam-
age. Replace if necessary.
NOTE:
Take care to insure that the bypass rod
is free of burrs that may cut the rubber
lip seal.
2. Inspect the housing bore.
Assembly
1. Reassemble all parts in the reverse order
of disassembly.
2. Install a
new
lip seal (30).
3. Install the bypass rod (32) with
new
clip
retaining ring (31), if removed.
4. Install the new retaining ring (33).
5. Install the bypass arm (34).
6. Install the retaining ring (35).
Figure 21, Bypass Arm and Rod
30
31
32
33
34
35