2-2 - Tool Operation
Begin Cleaning
1.
Attach the solution hose to the
Solution Quick Connect
. A 1 ½” vacuum hose can
be attached to the
Vac Hose Manifold
(see Figure 2-3).
2.
Adjust the water volume by turning the
Solution Control Knob
(see Figure 2-3).
By turning the knob counterclockwise, the water volume will increase. By turning
the knob clockwise, the water volume will decrease. The amount of water volume
you need will vary with the type of machine you are cleaning with and the type of
material you are cleaning.
To begin adjustment, make sure the machine is running, and both vacuum and so-
lution hoses are connected. Slowly open the
Solution Control Knob
until water
is flowing across the entire bar jet (without overspray).
Do not use the DriMaster HiFlo Upholstery Tool on a machine set above 14” Hg vacuum
and 500 psi solution pressure.
Solution Quick Connect
Vac Hose Manifold
Solution Control Knob
Solution Bar Jet
Figure 2-3. Attach Solution Hose and Adjust Water Volume