6 | Manual operation
HYDAC FILTER SYSTEMS GMBH
68 / 120
BeWa MFU-10P 4391553c en-us web
2.
Connect the pressure hose to the oil tank/container and
fit the pressure hose in it and also secure it against
falling out.
3.
Connect the filter unit to the voltage source.
4.
Switch the filter unit on at the main switch.
5.
Keep an eye on the display of the ContaminationSensor
with the respectively current cleanliness class.
6.
If the display of the ContaminationSensor shows the
required or a better cleanliness class, switch the filter
unit off.
7.
Release the pressure hose at the quick coupling, see
Removing/installing the quick coupling [
.
8.
Empty the contents of the pressure hose into the oil
tank/container.
9.
Empty the contents of the suction hose into the oil tank/
container.
10.
Secure the pressure hose at the quick coupling, see
Removing/installing the quick coupling [
.
11.
Secure the cable and, if required, the hoses to the filter
unit, see
.
O
Cleaning up to the required cleanliness class is
complete.