5 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
54 / 120
BeWa MFU-10P 4391553c en-us web
5.4.3 Connecting filter units with a power plug for 400
V AC, 3 phases
The unit with a 3-phase electric motor is fitted with a main
switch, motor protection and connection plug.
Connect the unit according to the following steps.
1.
Remove the power supply cable from its bracket and
unwind it completely.
2.
Before inserting the power plug, ensure that the main
switch is in the 0 or OFF position.
3.
Ensure that the voltage and frequency are correct. You
will find the electrical data of the filter unit on the name
plate of the electric motor.
4.
Plug the power plug into a suitable power outlet.
5.
Check the direction of rotation of the electric motor by
switching it on briefly (jog mode). The direction of
rotation required is indicated by an arrow on the fan
cover.
6.
If the direction of rotation needs to be changed, this can
be done by turning the phase inverter in the connection
plug as per the adjacent figure.
7.
Switch the filter unit on at the main switch.
ð
The motor pump group begins to pump. The direction
of rotation is according to the arrow on the fan cover
of the electric motor.
8.
Switch the filter unit off at the main switch.
O
The filter unit is connected electrically.