14. Rotate the element set by 180°.
Insert the element set into the
coalescing housing.
Note that the element set fits only in
one position (Z) in the coalescing
housing.
15. Clean the sealing surface on the
cover.
Check the O-ring for damage. Replace
it if necessary.
16. 1 - Place the cover on the coalescing
housing.
2 - Place the housing clamp over the
coalescing housing.
17. Use an SW 13 fork wrench to tighten
the tensioning clamps evenly to a
maximum of 20 Nm.
Screw open the lock nut and secure
the connection.