Performing maintenance
LVU-CD-40
en(us)
Page 47 / 68
BeWa LVU-CD-40 4035823a en-us 2016-01-08.doc
2016-01-08
8.
Now place the filter bowl cover on the
new filter element and lock it in place.
9.
Fasten the dirt catch tray to the bottom
end of the filter element.
10. Check the O-ring on the cover for correct
seating.
Place the filter element with the cover
and dirt catch tray in the filter housing.
11. Secure the cover with the housing clamp.
The tightening torque is a maximum of 5
Nm.
12. Screw in the drain screw (Drain) at the
connection part of the unit and tighten.
Switch the filtration unit on.
Bleed the filter housing through the air
bleed plug (Air Bleed) in the filter cover.