Performing maintenance
LVU-CD-40
en(us)
Page 45 / 68
BeWa LVU-CD-40 4035823a en-us 2016-01-08.doc
2016-01-08
Replacing the filter element in the filter housing
The filter element has a bayonet seal - this simplifies changing the element.
The only intervention required is to turn the element or its mounting parts 90°
clockwise or counterclockwise.
1.
Switch off the installation, make sure that
no operating fluid can flow out of the
lines into the filtration unit, and make
sure that the unit cannot be switched on
again during maintenance.
Depressurize the filter housing. To
accomplish this, carefully open the drain
plug (Air Bleed) on the filter housing
cover (do not unscrew completely).
Be careful when the operating
fluid flows out.
2.
Put a suitable container in place to catch
the fluid in the filter housing.
The content is
≈
3 or 6 liters.
Empty the filter housing through the drain
screw (Drain) on the connection part.
Without the proper drainage
equipment, the draining fluid could flow
downward to the electric motor.
3.
Loosen the tensioning clamp on the filter
housing cover by completely unscrewing
the nut.
Remove the housing clamp.