5 | Installation / Assembly
HYDAC FILTER SYSTEMS GMBH
34 / 52
MoWa LVH-CD-AWD 4650237 en-us web
5.3.1 Setting the time interval
Set the time interval according to the set size at the time relay
K3, see circuit diagram.
K3
Below you will find a summary table with the time setting per
size of the coalescer housing.
Size
LVH-CD
Vertical
coalescing housing
Horizontal
coalescing housing
240
7 seconds
8 seconds
440
16 seconds
22 seconds
640
7 seconds
7 seconds
940
11 seconds
9 seconds
1240
-
6 seconds
1940
-
6 seconds
Tab. 7: Setting the time interval