Technical data
Technical Data FMM
Mounting position
vertical, with the direction of flow from bottom
to top.
Operating pressure, maximum
15 bar / 217 psi
Minimal differential pressure
1 bar, recommended
≥
3 bar
Connectors (IN / OUT)
Test point type 1604 or
thread G 1/4 according ISO 228
Sealing material
FPM
Permissible viscosity range
1 ... 1000 mm²/s
Fluid temperature range
0° ... 85° C / 32° ... 185° F
Ambient temperature range
0° ... 80° C / 32° ... 176° F
Weight
4.3 kg
For further technical details, please refer to the operating and maintenance manuals