Maintenance
FAM 5
en-US
Page 134 / 148
BEWA FAM5 4166129a en-us 2019-03-04.docx
2019-03-04
Checking the AquaSensor AS1000
Check the AquaSensor annually with the calibration and adjustment set. See
chapter “Accessories“, page 137. You can find further information in the
calibration and adjustment set instruction manual.
Replace the AquaSensor if it exhibits great deviations.
Checking the float switch in the oil pan
Proceed as follows to test the float switch:
1.
The unit is in operation.
2.
Use your fingers to raise the float switch in
the oil pan.
3.
The unit must switch off after ≈ 3 seconds.
4.
Release the float switch and acknowledge the error.
5.
Start up the unit.
6.
The function of the float switch is thus ensured and the check has
been successfully completed.