14
EDS
300
Status: 19.09.2018
HYDAC ELECTRONIC GMBH
Part No.: 669648 E
12 Technical specifications
Input data
Measuring ranges
16 | 40 | 100 | 250 | 400 | 600 bar
Overload pressures
32 | 80 | 200 | 500 | 800 | 1000 bar
Burst pressure
200 | 200 | 500 | 1000 | 2000 | 2000 bar
Mechanical connection
G1/4 A ISO 1179-2
Torque value, recommended
20 Nm
Parts in contact with medium
Mech. connection: Stainless steel
Seal: FPM
Output data
Switching outputs
1 or 2 PNP transistor outputs
Switching current: max. 1.2 A per switch output
Switching cycles: > 100 million
Analogue output, permitted load resistance
4 .. 20 mA load resistance max. 400
Ω
Accuracy to DIN 16086,
Max. setting
≤
± 0.5 % FS typ.
≤
± 1 % FS max.
Temperature kompensation zero point
≤
± 0.02 % FS / °C typ.
≤
± 0.03 % FS / °C max.
Temperature kompensation range
≤
± 0.02 % FS / °C typ.
≤
± 0.03 % FS / °C max.
Repeatability
≤
± 0.5 % FS max.
Reaction time
approx. 10 ms
Long-term drift
≤
± 0.3 % FS typ. / year
Environmental conditions
Compensated temperature range
-10 .. +70 °C
Operating temperature range
-25 .. +80 °C
Storage temperature range
-40 .. +80 °C
Fluid temperature range
-25 .. +80 °C
-mark
EN 61000-6-1 / 2 / 3 / 4
Vibration resistance to
DIN EN 60068-2-6 at 10 .. 500 Hz
≤
10 g
Shock resistance to
DIN EN 60068-2-27 (11ms)
≤
50 g
Protection class to DIN EN 60529
1)
IP
65
Other data
Supply voltage
20 .. 32 V DC
Current consumption
approx. 100 mA (inactive switch output)
Display
3-digit, LED, 7 segment, red,
height of digits 9.2 mm
Weight
̴
300 g
Note:
Reverse polarity protection of the supply voltage, excess voltage,
override, short circuit protection are provided.
FS
(
F
ull
S
cale) = relative to the complete measuring range
1)
With mounted female connector having the corresponding protection class