CSM 2000 Series
Starting up the CSM
Starting up the CSM
You must adjust the counter balance valve (A) once the CSM has been connected
hydraulically to the entire system with IN/OUT, and with LEAKAGE if applicable, and
the electrical connection has been completed.
The counter balance valve (A) and the throttle valve (B) are completely open at the
time the unit is shipped.
Adjusting the counter balance valve
Required tools and measuring instruments
Open-jaw wrench, size 22 mm
Open-jaw wrench, size 13 mm
Allen wrench, size 4 mm
Pressure gauge 0-40 bars, including adapter
(comes standard with the CSM)
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 26 / 40
BeWa CSM2000 3211683h en-us 2011-12-01.doc