8.
Press the new filter element down
into the filter mount by turning it
slightly.
Do not use striking tools for this.
9.
Check the O-ring on the cover for
damage and replace it if necessary.
Lightly wet the O-ring on the cover
with medium.
10. Put the cover on.
Observe correct placement of
the O-ring on the cover while doing
so. It must not be damaged.
11. Fold the four screws up and turn
them clockwise evenly crosswise.