Putting the filter housing out of operation
Putting the filter housing out of operation
Empty the filter housing completely, including all of its components, before
decommissioning.
Shutting down filter housing
See chapter "Putting the filter housing out of operation"
Disposing of the filter housing
After dismantling the filter housing and separating its various materials,
dispose of it in an environmentally friendly manner.
Technical details
TECHNICAL DATA
Number of filter elements
17 pcs.
Housing material
1.0305, 1.0038 / 1.4301 or
better
Vessel volume
≈ 130 liters
Permitted operating pressure
≤
10 bar
Material of seal
FKM / NBR / EPDM
Weight when empty
≈ 165 kg
Permitted operating temperature range
-10 … 90 °C / 14 … 194 °F
Permitted ambient temperature range
5 … 30 °C / 41 … 86 °F
Permitted storage temperature range
5 … 30 °C / 41 … 86 °F
Permissable relative humidity
≤
50% (non condensing)
Hydraulic connection (IN, OUT)
EN1092-1/11/B1/80/16
MRF4
en(us)
Page 32 / 36
MoWa MRF4 3214670d en-us 2018-02-09.docx